Service Manual-AS1050R
04 Control System 41
Main Controller (EB2) Parameter Setting
NO. Parameter Name
Value
Unit
Comment
81
Bru Unload Rate
0.1
Seconds
Brush release deceleration rate
82
Bru load Rate
0.1
Seconds
Brush installation acceleration rate
83
Bru load Down T
5
Seconds
Brush installation down time
84
Bru load Curr
35
A
Brush installation in place current value
85* Bru I Limit
90
A
Brush motor current limiting value
86* Bru Stall Time
10
Seconds
Brush motor overcurrent protection time
87
Bru SW Control
0
N/A
Reserved
88
Bru AutoAdjust
7
N/A
Brush pressure auto adjustment mode. 7-Time control
89
Bru Adjust T1
50
A
Reserved
90
Bru Adjust T2
50
A
Reserved
91
Bru Adjust T3
50
A
Reserved
92
Bru Adjust Tol
3
A
Reserved
93
No Bru I Limit
0
A
No brush current value. 0-Disable
94
No Bru Limit
15
Seconds
No brush diagnosis time
95
Bru I Check Tim
50
N/A
Reserved
96
Bru I Adj FCT
10
N/A
Reserved
97
Vac TopSpeed
35
V
Vacuum motor maximum voltage
98
Tra Enab Vac
0
N/A
Traction motor enabling vacuum motor. 0-Disable
99
Vac Off In RVS
0
N/A
Vacuum motor off in reverse. 0-Not off, 1-Off
A0 Vac Accel Rate
1.8
Seconds
Vacuum motor acceleration rate
A1 Vac Decel Rate
1.8
Seconds
Vacuum motor deceleration rate
A2 Vac PowOff Dec
1.2
Seconds
Vacuum motor power off deceleration rate
A3* Vac I Limit
50
A
Vacuum motor current limiting value
A4* Vac Stall Time
3
0.1S
Vacuum motor overcurrent protection time
A5 Vac SW control
0
N/A
Reserved
A6 Vac Off DelayT
0
Seconds
Vacuum motor on delay time
A7 Vac Off DelayT2
0
Seconds
Vacuum motor off delay time
A8 Squ BruDExcha
0
N/A
Reserved
A9 Squ TopSpeed
32
V
Squeegee actuator maximum voltage
B0
SquUpInRVS
2
N/A
Squeegee up in reverse. 2-Up
B1
Squ Accel/Dece
0.5
Seconds
Squeegee actuator acceleration and deceleration rate
B2* Squ I Limit
2
A
Squeegee actuator current limiting value
B3* Squ Stall Time
2
0.1S
Squeegee actuator overcurrent protection time
B4
Squ Up Delay T
0
Seconds
Squeegee up delay time
B5
Squ Dw Delay T
1
Seconds
Squeegee down delay time
B6
Vac Master Squ
1
N/A
Vacuum motor enabling squeegee actuator. 0-Enable, 1-
Disable
B7
Squ UpStop Mod
1
N/A
Squeegee up stop mode
B8
Squ DwStop Mod
1
N/A
Squeegee down stop mode
B9
Squ UpStop Tim
3.5
Seconds
Squeegee up stop time
C0 Squ DwStop Tim
3.5
Seconds
Squeegee down stop time
C1 Squ UpStop I
2
A
Squeegee up stop current
Содержание 50000593
Страница 11: ...Service Manual AS1050R 03 General Information 11 Machine Structure Figure 2 ...
Страница 12: ...Service Manual AS1050R 03 General Information 12 Machine Structure continues Figure 3 ...
Страница 13: ...Service Manual AS1050R 03 General Information 13 Control Panel Figure 4 ...