121
Menu Key
5
When you input a Stn-XYZ by Base-XYZ function, the
recorded station appears as a comment record.
SY records
When you complete a station setup, a SY record is
stored. This record contains the Temperature, Pressure,
and Prism Constant values.
RM records
When you record measurements in RDM (Cont) or
RDM (Rad), they are labeled as RM records.
Each RM record consists of two screens.
Press
[DSP]
to switch between the first screen (showing
From, To, rHD, and rVD) and the second screen
(showing rAZ, rSD, rV%, and rGD).
When you download data in Nikon RAW format, RM
records are output as comment (CO) records.
AR records
An AR record stores an area and perimeter calculation.
When you download data in Nikon RAW format, AR
records are output as comment (CO) records.
View coordinate data
When you press
[2]
or select
XYZ data
in the Data
menu, coordinate data appears in a list, with the newest
record at the bottom of the screen. Use
[^]
or
[v]
to scroll
through the records. Use
[<]
or
[>]
to move up or down
one page.
Содержание NPL-322
Страница 14: ...Contents xiv Total Station NPL 322 Instruction Manual ...
Страница 38: ...2 Preparation 24 Total Station NPL 322 Instruction Manual ...
Страница 68: ...3 Getting Started 54 Total Station NPL 322 Instruction Manual ...
Страница 110: ...4 Applications 96 Total Station NPL 322 Instruction Manual ...
Страница 154: ...5 Menu Key 140 Total Station NPL 322 Instruction Manual ...
Страница 161: ...Total Station NPL 322 Instruction Manual 147 Checking and Adjustment 6 ...
Страница 162: ...6 Checking and Adjustment 148 Total Station NPL 322 Instruction Manual ...
Страница 169: ...C H A P T E R 8 Total Station NPL 322 Instruction Manual 155 System Diagrams 8 In this chapter System Components ...
Страница 172: ...8 System Diagrams 158 Total Station NPL 322 Instruction Manual ...
Страница 188: ...9 Communications 174 Total Station NPL 322 Instruction Manual ...