Total Station NPL-322 Instruction Manual
181
Error Messages
10
NO Stn Setup
100.27
You did not perform a station setup or BS check before entering the Stakeout
function.
B
Tip –
Selecting
Continue
does
not
resume the last ST record. You should only use the
Continue
option if you are sure that the previous ST coordinates and the current HA
orientation are correct. Otherwise, records in the Stakeout function may not be correct.
Station Setup
Calc ST Failed Need additional PT
100.28
Calculating ST failed in resection. This message may appear after you have deleted a
point the View shots screen.
Press any key to return to the PT input screen. Take another shot to calculate the ST
coordinate.
Same Coordinate
100.29
The input PT or coordinate is identical to the current station in STN/1:Known, or the
same coordinate or point name/number is found in Resection.
Press any key to return to the PT input screen. Then use a different PT.
Space LOW
100.30
There is not enough space to record a station when you start any of the Station Setup
functions.
XY-coordinate is required
100.31
The input point for ST/BS does not have N/E coordinates.
Press any key to return to the PT input screen. Then use a PT that has N/E
coordinates.
To...
Press ...
go to the Stn Setup menu
[2]
or select
Stn Setup
return to the Basic
Measurement Screen (BMS)
[ESC]
go to the Stakeout menu
[1]
or select
Continue
To ...
Press ...
return to the BMS
press
[ESC]
or the
Abrt
softkey. Use the
DEL
softkey in Job Manager to delete old jobs.
continue
press
[ENT]
or the
OK
softkey. You may not be able to
record the whole process.
Содержание NPL-322
Страница 14: ...Contents xiv Total Station NPL 322 Instruction Manual ...
Страница 38: ...2 Preparation 24 Total Station NPL 322 Instruction Manual ...
Страница 68: ...3 Getting Started 54 Total Station NPL 322 Instruction Manual ...
Страница 110: ...4 Applications 96 Total Station NPL 322 Instruction Manual ...
Страница 154: ...5 Menu Key 140 Total Station NPL 322 Instruction Manual ...
Страница 161: ...Total Station NPL 322 Instruction Manual 147 Checking and Adjustment 6 ...
Страница 162: ...6 Checking and Adjustment 148 Total Station NPL 322 Instruction Manual ...
Страница 169: ...C H A P T E R 8 Total Station NPL 322 Instruction Manual 155 System Diagrams 8 In this chapter System Components ...
Страница 172: ...8 System Diagrams 158 Total Station NPL 322 Instruction Manual ...
Страница 188: ...9 Communications 174 Total Station NPL 322 Instruction Manual ...