JAA80151-R.3718.A
-
A 4・AF-S 4-24/2.8G
-
● In case of replacing the main PCB and SWM unit, GMR sensor or focus turning-tube, be sure to make
adjustments.
・
Turn the constant-voltage power supply ON.
・
Confirm that the electric current and voltage of the connected constant-voltage power supply are set to
the set values, which are instructed on the PC screen.
・
Select "1. Adjustment for Electrical Device". The lens starts scanning-drive automatically.
・
When the "Auto-adjustment for electrical device is completed" appears, the adjustment is finished.
C H 1 = 5 V C H 2 = 5 V 5 m s / d i v
D C 1 0 : 1 D C 1 0 : 1
NORM 200KS/s
●
Oscilloscope setting
V/Div
(
CH1
)
:5V
V/Div
(
CH2
)
: 5V
Coupling
: DC
Time/Div
: 1m Sec
Trigger Mode
: NORMAL
Trigger Coupling
: DC
Trigger Source
: CH1
Trigger Position
:
+
4div
Trigger Type
: EDGE
Trigger Level
: 2.5V
Adjustment for electrical device
INC