JAA80151-R.3718.A
- A ・AF-S 4-24/2.8G -
#96×2
Adhesive: Lockend B
Focus coupling key
Grease: I-40
Apply to the key groove.
Set the zoom of the inner fixed tube to WIDE position.
Set the roller pin of the 2nd lens-G unit to the rightmost position.
Insert the focus coupling key in "A" section of the focus turning-tube, and put the roller pin in the
key groove.
�
�
�
Focus coupling key
Inner fixed tube
"A" section
Roller pin
Focus turning-tube
Key groove
Tighten two screws (#96).
�
INC