WARNING: THERE IS TO BE NO PERSON IN THE BASKET WHEN THE BASKET IS BEING 
LEVELLED USING THE BASKET TRIM FUNCTION. FAILURE TO FOLLOW THIS WARNING MAY 
RESULT IN SERIOUS INJURY. 
 

  To operate the base controls, located at the base of the machine, the control selector switch located 

on the electrical enclosure on the base, must be switched to the base controls position. 

 

  To operate a function, push the deadman lever, located at the left hand end of the base controls, in 

the direction indicated on the sign and then move any of the EWP functions; bottom boom lift, top 
boom lift, tele boom extension, slew, and basket trim, to achieve the desired motion. 

 

Emergency Controls and Emergency Basket Retrieval 

 

The Nifty Lift RKT range of Elevating Work Platforms are equipped with different power sources which 
may be used to lower the basket and stow the machine in the event of vehicle engine break down.  

 
 

1: Accumulator (If fitted) 
 

If engine power is lost and cannot be regained, the booms may be brought to the stowed position, or the 
basket lowered to the ground, using the reserve of hydraulic fluid in the accumulator. In this situation, 
work platform controls may be operated, from either the basket or the base, in the same manner as 
when the engine is running. The accumulator, located on the vehicle, is kept charged (i.e. pressurised), 
while the vehicle engine is running, during normal operation of the work platform. When charged, it holds 
a volume of hydraulic oil, under pressure, adequate to stow the tower.  In addition to stowing the tower, 
there may be enough oil left to raise the stabiliser legs. This depends on the initial position from which 
the booms are stowed.  

 
2: Emergency DC Pump (If fitted) 

 

If engine power is lost, the emergency pump may be used to operate the machine. To operate a boom 
function using the emergency pump, move the control lever on the control valve, in the base, that 
corresponds to the function and direction required. Then push the deadman lever to the deadman 
position and also depress the emergency pump button, located above the deadman lever, 
simultaneously. 

 

To operate the stabiliser legs, using the emergency pump, move the stabiliser control lever, on the 
control valve, that corresponds to the function and direction required and then push the emergency 
pump button. 

 

3: Emergency Hand Pump (If fitted) 

 

If engine power is lost and the emergency pump will not operate, the emergency hand pump may be 
used to operate the machine. 
 

  Ensure that the lever on the side of the hand pump itself is in the “ENGAGE” position, i.e. pointing 

towards the base structure. 

 

  Place the hand pump handle, located on the pedestal, into the socket on the pumping lever at the 

end of the hand pump. 

 

  Move, and hold, the lever corresponding to the desired function and then pump the hand pump using 

the extension handle, located on the pedestal. 

 

 
 
 
24.01.91

 

Содержание NL140RKT

Страница 1: ......

Страница 2: ......

Страница 3: ...IN THE BASKET TO INCREASE HEIGHT DO NOT ANCHOR THE BASKET TO ANY STRUCTURE DO NOT RAISE THE BASKET IF THE MACHINE IS NOT LEVELLED WITHIN THE 5o LIMIT DISPLAYED ON THE LEVEL BUBBLE DO NOT STAND ON THE...

Страница 4: ...S OR REAR ONLY STABILISERS MUST NOT BE USED ON SIDE SLOPE IF THE MACHINE IS TO BE OPERATED ON A SIDE SLOPE IT MUST BE POSITIONED SO THAT THE VEHICLE IS FACING UP THE SLOPE I E THE CAB OF THE VEHICLE I...

Страница 5: ...k located at the centre of the transmitter must be moved and held either to the left or to the right as indicated Once the deadman has been activated the EWP functions bottom boom lift top boom lift t...

Страница 6: ...d of time the engine may be stopped by pressing the ENGINE START STOP button When required the engine may be started again by pressing the ENGINE START STOP button again Emergency DC Pump GROUND trans...

Страница 7: ...ng The accumulator located on the vehicle is kept charged i e pressurised while the vehicle engine is running during normal operation of the work platform When charged it holds a volume of hydraulic o...

Страница 8: ...CKOUTS WILL NOT OPERATE UNLESS THE TOP BOOM OF THE WORK PLATFORM IS STOWED WARNING DEFLATE AIRBAG SUSPENSION IF FITTED BEFORE ENGAGING SPRING LOCKOUTS To operate the spring lockouts depress the deadma...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ...NIFTY LIFT SYSTEM COMPONENTS CIRCUIT DIAGRAMS 24 00 18...

Страница 16: ......

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...I19 I10 I9 I11 I12 Q6 Q5 I13 I14 I15 I16 I17 I18 Q8 Q7 Q9 Q10 Q11 Q12 Q13 Q15 I20 Q14 Q16...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ...DC PUMP POWER TOOLS ENGINE START STOP UPPER BOOM LOWER UPPER BOOM RAISE LOWER BOOM LOWER BOOM EXTEND BOOM RETRACT SLEW CW LOWER BOOM RAISE SLEW CCW NIFTY LIFT N12335 DEADMAN F3 Z3H G2 Z2L F2 Z2H G3 Z...

Страница 26: ...ar with mechanical procedures Before operating the machine the operator must be sure that the machine has been properly maintained The operator should carry out the daily inspections described in this...

Страница 27: ...eck guardrails sideboards and floors for damage Inspect critical welds at base and frame for signs of cracks damage or distortion Check pins and bushes for wear Check condition of insulation covers bo...

Страница 28: ...f damaged or missing Check all Emergency systems emergency batteries and charging system operation of electric pump and emergency controls Check for correct operation of spring lockouts and or stabils...

Страница 29: ...mage or hose wire damage Check speed of all operations see separate spec sheet Check directional arrows function correctly if fitted Check revolving lamps if fitted Electrical test unit Fill out opera...

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ...nd Serien nummer G PVM Woche und Jahr der Herstellung C PVG num ro semaine et ann e de montage et num ro s riel D PVP r glage de pression E PVP num ro semaine et ann e de fabrication et num ro s riel...

Страница 37: ...Nm Weicheisen Dichtring 1150 lbf in 1850 lbf in 1150 lbf in 1850 lbf in 350 lbf in 150 lbf in 350 lbf in avec rondelle en acier med kobberskiv with copper washer 30 Nm 50 Nm 30 Nm 50 Nm 20 Nm 15 Nm 20...

Страница 38: ...le de 22 5 C H ndtaget skal skrues helt i bund C Screw the lever completely home C Den Hebel v llig einschrauben C Visser le manipulateur entierement au fond Fod med en vinkel p 37 5 Base with an angl...

Страница 39: ...15 V 22 30 V Pin 1 2 1 2 Q P A UDC 0 UDC 0 Q P B 0 UDC 0 UDC Neutral 0 0 0 0 UDC 11 15 V 22 30 V Pin 1 U 2 US 1 U 2 US Q P A UDC 0 5 0 25 x UDC UDC 0 5 0 25 x UDC Q P B UDC 0 5 0 75 x UDC UDC 0 5 0 75...

Страница 40: ...V 22 30 V Pin 1 2 1 2 Q P A 0 UDC 0 UDC Q P B UDC 0 UDC 0 Neutral 0 0 0 0 UDC 11 15 V 22 30 V Pin 1 U 2 US 1 U 2 US Q P A UDC 0 5 0 75 x UDC UDC 0 5 0 75 x UDC Q P B UDC 0 5 0 25 x UDC UDC 0 5 0 25 x...

Страница 41: ...id valve B Magnetventil B Electrodistributeur Gr n Green Gr n Vert A Eksternt rel A External relay A Externes Relais A Relais externe B Magnetventil B Solenoid valve B Magnetventil B Electrodistribute...

Страница 42: ...tagsvandring i neutralstilling 1 S t hydraulisk tryk p systemet 2 Tilslut forsyningssp nding UDC Signalsp nding 0 5 x UDC eller afbryd signalsp nding US Check max lever travel in neutral position 1 Ma...

Страница 43: ...aulic build up of PVEK it may be necessary to bleed the PVEK A non bleed PVEK may among others give rise to abnormal vibrations in the PVEM lever Udluftning wenn die Gruppe vertikal montiert ist empfe...