background image

10

GENERAL INFORMATION

Installation guide Powerdrive MD Smart Equipment

5704 en - 2021.10 / b

Rating

Ambient 

temperature

INVERTER

RECTIFIER 400V

RECTIFIER 480V

Isp output current

(A)

Power supply current

Power supply current

Normal duty

Heavy duty

Imax 

3s

(A)

Imax 

60s

(A)

Input 

current

(A)

Imax

60s

(A)

Idc

(A)

Input 

current

(A)

Imax

60s

(A)

Idc

(A)

3kHz 4kHz 6kHz 8kHz 3kHz 4kHz 6kHz 8kHz

75TN

40°C

139 130.8 114.6 100.3 110 101.2 88.82 77.36

175 161

130

201

159

108

167

132

50°C

126 119 104

91

99

92

80

70

118

144

98

120

120TN

40°C

202 171.9 145.2 125.1 159 153.8 129.9 112.7

254 233

196

303

240

157

243

192

50°C

183 155.7 131.5 113.3 144 139.3 117.6 102.1

177

217

142

174

150TN

40°C

248 229.2 189.1 159.5 195 193.9 160.4 134.7

312 286

235

369

282

215

338

263

50°C

225 207.6 171.3 144.5 177 175.6 145.3 122

213

255

195

238

180TN

40°C

301 278.9 229.2 193.9 236 230.2 189.1 160.4

378 347

282

443

345

263

413

322

50°C

272 252.6 207.6 175.6 214 208.5 171.3 145.3

255

312

238

291

220TN

40°C

390 367.7 324.7 286.5 306 295.1 259.8 230.2

490 449

377

593

462

311

489

381

50°C

353 333 294.1 259.5 277 267.3 235.3 208.5

342

419

282

345

270TN

40°C

475 434.5 372.5 321.8 373 341.9 293.2 253.1

596 547

457

719

538

367

576

449

50°C

430 393.6 337.4 291.5 338 309.7 265.6 229.2

414

487

332

407

340TN

40°C

590 530 437.4 369.6 464 416.4 343.8 290.3

742 680

568

893

678

456

716

558

50°C

535 480.1 396.2 334.8 420 377.1 311.4 263

515

614

413

505

430TN

40°C

713 654.2 560.6 484.2 561 513.8 440.3 380.1

896 822

669

1052

800

544

855

667

50°C

646 592.5 507.8 438.6 508 465.4 398.8 344.3

606

725

493

604

470TN

40°C

826 756.4 639.9 549.1 649 594 503.3 431.7

1038 952

796

1250

926

630

990

772

50°C

748 685.1 579.6 497.4 588 538 455.9 391

721

839

571

699

570TN

40°C

889 816.5 659 568.2 699 641.8 517.6 446.9

1117 1024

856

1344

1009

687

1079

841

50°C

805 739.6 596.9 514.7 633 581.3 468.8 404.8

775

914

622

762

680TN

40°C

1145 1028 848.5 717 900 807.8 667 563.2

1439 1319

1061

1667

1248

884

1389

1083

50°C

1037 931.3 768.6 649.4 815 731.7 604.1 510.1

961

1131

801

981

860TN

40°C

1384 1269 1088 939.3 1087 996.8 854.1 737.4

1739 1594

1282

2013

1570

1070

1680

1310

50°C

1254 1149 985 850.8 985 902.8 773.6 667.9

1161

1422

969

1187

940TN

40°C

2603 1467 1241 1065 1259 1152 976.4 837.4

2014 1846

1481

2327

1814

1237

1943

1515

50°C

1452 1329 1124 964.9 1141 1044 884.4 758.5

1342

1643

1120

1372

1140TN

40°C

1725 1584 1278 1102 1355 1245 1004 867.1

2167 1987

1598

2510

1957

1331

2091

1630

50°C

1562 1435 1158 998.5 1228 1128 909.5 785.4

1447

1772

1206

1477

1290TN

40°C

2055 1884 1614 1394 1614 1480 1268 1095

2582 2366

1903

2990

2331

1586

2492

1943

50°C

1861 1706 1462 1263 1462 1340 1148 991.5

1724

2111

1437

1760

1410TN

40°C

2379 2178 1843 1581 1869 1711 1449 1243

2989 2740

2204

3462

2700

1836

2885

2249

50°C

2155 1973 1669 1432 1693 1550 1313 1126

1996

2445

1663

2037

1710TN

40°C

2561 2352 1898 1636 2012 1848 1491 1287

3218 2949

2345

3683

2871

1954

3069

2393

50°C

2319 2130 1719 1482 1822 1674 1350 1166

2124

2601

1770

2168

2280TN

40°C

3379 3103 2504 2159 2655 2439 1967 1698

4245 3892

3094

4860

3790

2579

4050

3158

50°C

3060 2810 2268 1956 2404 2209 1782 1538

2803

3432

2336

2860

2850TN

40°C

4223 3878 3130 2699 3318 3048 2459 2123

5307 4864

3913

6146

4792

3260

5121

3993

50°C

3825 3513 2835 2445 3006 2761 2227 1923

3544

4340

2953

3617

Содержание LEROY-SOMER

Страница 1: ...Part number 5704 en 2021 10 b Powerdrive MD Smart Equipment MD3 serie Installation guide High power free standing drive solution...

Страница 2: ...takes appropriate precautions against the motor restarting after an unscheduled stop The drive s which form part of this equipment is are designed to be capable of supplying the motor s associated wi...

Страница 3: ...ce between components during transportation and handling Avoid touching the electronic components and contact parts Variable speed drives contain parts that are sensitive to electrostatic stresses and...

Страница 4: ...yneo motor Compabloc Axial output Helical gears According to the electrical plan TH No located in the cabinet document holder these drawings are produced in their entirety by the Electrical design ser...

Страница 5: ...wer terminal block location 18 3 1 4 Cables and fuses 18 3 2 Connection of the control 20 3 2 1 Control terminal block location 20 3 2 2 Control terminal block characteristics 20 3 2 3 Factory configu...

Страница 6: ...1 4 Special settings 32 5 2 Add on options 33 5 2 1 Fieldbus options 33 5 2 2 Speed feedback options 33 5 2 3 Additionnal I O options 33 5 3 Braking modules and associated resistors 34 5 3 1 Braking...

Страница 7: ...Front view of the cabinet with the various dimensions Bottom view for fixing to the floor Various terminal block connection diagrams Parts list giving details of the equipment The equipment used is E...

Страница 8: ...ns where significant inertia has to be accelerated quickly centrifuges translation of travelling cranes etc Normal duty For low overload constant torque or centrifugal torque machines fans compressors...

Страница 9: ...50 3110 2851 1 Motor winding voltage Frequency Hz Ico or Imax 60 s 1 4 3 Derating at low frequency Measuring the temperature of the power bridges in conjunction with thermal modelling of the IGBTs ens...

Страница 10: ...06 725 493 604 470TN 40 C 826 756 4 639 9 549 1 649 594 503 3 431 7 1038 952 796 1250 926 630 990 772 50 C 748 685 1 579 6 497 4 588 538 455 9 391 721 839 571 699 570TN 40 C 889 816 5 659 568 2 699 64...

Страница 11: ...376 281 221 325 296 221 174 368 451 570TH 40 C 516 439 329 260 406 397 298 235 648 594 497 770 608 50 C 467 398 298 235 368 360 270 213 450 551 680TH 40 C 728 661 497 389 572 521 391 306 922 838 699 1...

Страница 12: ...a baseplate 100 mm high is installed as standard to ensure the rigidity of all the drive cabinets and for lifting them if necessary refer to the drawing of the device supplied in the THxxxxx plan 2 M...

Страница 13: ...a means of evacuating the hot air expelled by the product If necessary add a suction hood Never obstruct the drive ventilation grilles the air intake filters must be cleaned and changed regularly Aft...

Страница 14: ...e masses losses and flow rates of the Powerdrive MD Smart equipment are specific to each configuration resulting from the customer s specifications To obtain them please contact Moteurs Leroy Somer IN...

Страница 15: ...sition will be detailed on the layout diagram of the TH plan To avoid condensation in the drive cabinet Respect the temperature of the liquid cooling indicated in the table below Stop the liquid circu...

Страница 16: ...is used it is recommended to add an inhibitor to prevent electrochemical corrosion If there is no external loop this corrosion shall be avoided by using materials compatible with the materials used i...

Страница 17: ...is advisable to install a circuit breaking device between the permanent magnet motor and the drive output to eliminate the risk of hazardous voltage feedback when performing maintenance work Also com...

Страница 18: ...short circuit current Isc 20 IL at the point of drive connection This table is given for information only and must under no circumstances be used in place of the current standards IL Maximum line curr...

Страница 19: ...ation configuration and located at the start of the line 2 The recommended AC supply cable cross sections have been determined for single core cable with a maximum length of 20 m For longer cables tak...

Страница 20: ...mmon mode 24 V 0 V Voltage mode Input impedance 50 k Absolute maximum voltage range 30V Current mode Input impedance 100 Absolute maximum current 30 mA 3 2 Connection of the control The Powerdrive MD...

Страница 21: ...ed fuse 2 5A An external supply connected to the 24V terminal will maintain the control supply in the event of a mains loss 2 DO1 Digital output Factory setting Zero speed Characteristics Open collect...

Страница 22: ...input 2 Run FWD Stop Run REV Stop Note This configuration has been obtained from a drive with factory settings default parameter settings The STO 1 and STO 2 inputs must be closed before giving a run...

Страница 23: ...fety components which must be incorporated in the complete system dedicated to machine safety As for any installation the complete machine must be subject to a risk analysis The integrator must determ...

Страница 24: ...Radio frequency interference Immunity 4 2 1 General The immunity level of a device is defined by its ability to operate in an environment which is contaminated by external elements or by its electric...

Страница 25: ...e it is essential to ensure that the harmonics generated by the commutation notches do not excessively distort the mains voltage and do not create voltage peaks with amplitude higher than 2 x mains Vr...

Страница 26: ...V PE PE PE Shielding A separate PE protective conductor is mandatory if the conductivity of the cable shielding is less than 50 of the conductivity of the phase conductor The shielding must be connec...

Страница 27: ...ble Level 4 industrially hardened EN 61000 4 4 Power cable Level 3 industrial IEC 61000 4 5 Shock waves Power cables Level 4 EN 61000 4 5 IEC 61000 4 6 Generic immunity standards for conducted radio f...

Страница 28: ...ectifier One module for the motor inverter The parameter setting interface is connected to the motor inverter module but may be connected to the active rectifier module for its initial configuration P...

Страница 29: ...erface displays the following screen Ready state Locked state In operation Local control Gives direct access to the motor control via the display Start Stop direction of rotation speed reference This...

Страница 30: ...ault or alarm Analog I O status Logical I O status 5 1 2 IHM Systemiz The new generation of high power drives is equipped with a secure wireless connection They are connected and smarter thanks to the...

Страница 31: ...omplete Systemiz apps available on iOS Android or Windows PC platforms some versions of Android or iOS may not be compatible with the apps It provides 3 features Product library direct access and down...

Страница 32: ...ion a wizard for initial start up of the drive and easy setup menus for quick setting after first start up advanced menus for experienced users or specific settings and password management Parameter f...

Страница 33: ...Powerdrive MD Smart MDX CM MODBUS Modbus RTU RS485 232 MDX CM ETHERNET Modbus TCP Ethernet MDX CM ETHERNET IP EtherNet IP MDX CM PROFIBUS Profibus DP V1 MDX CM PROFINET ProfiNet For more details consu...

Страница 34: ...a fire hazard A braking resistor must be mounted outside the drive cabinet as close as possible Ensure that it is incorporated in a grounded ventilated metal case to avoid any direct contact The braki...

Страница 35: ...and a number that can be used to identify the active trip see left hand column in the table below For trips numbered higher than 100 only the last 2 digits are displayed with a point displayed on bot...

Страница 36: ...heck the motor and cable insulation Run power diagnostics 10 Th rectifier Rectifier heatsink temperature too high Clean the cabinet dust filters Check the drive external and internal fans are working...

Страница 37: ...the stator resistance Check the motor wiring 34 Fieldbus loss Disconnection of the fieldbus during operation or timing error Check the fieldbus connections Check that parameter 15 07 is compatible wit...

Страница 38: ...have been complied with Check that the switching frequency 05 18 is compatible with the motor current level 59 IGBT W overheating Overheating of phase W IGBTs 60 Diagnostic Problem detected during th...

Страница 39: ...operations to be performed by the user on Powerdrive MD Smart drives Regular servicing operations are described below Servicing Printed circuits and drive components do not normally require any mainte...

Страница 40: ...Moteurs Leroy Somer Headquarter Boulevard Marcellin Leroy CS 10015 16915 ANGOUL ME Cedex 9 Limited company with capital of 38 679 664 RCS Angoul me 338 567 258 www leroy somer com 40041752...

Отзывы: