Installation - MANUBLOC 3000
4031 en - 2019.04 / i
INSTALLATION - DRIVE SYSTEMS - MANUBLOC 3000
2 - OPTIONS MOUNTING
2.1 - Shrink-disc
2.1.1 - Mounting
Remove all grease from shaft and hollow shaft bore.
1 -
Lightly oil the seating of the shrink-disc on the hollow shaft.
2 -
Draw shrink-disc onto hollow shaft. Slide shaft and hollow
shaft into one another.
3 -
Tighten the shrink disc screws, increasing the torque very
progressively to tightening torque indicated in the chart bellow.
It is normal that each screw must be tightened several times
until the torque is obtained.
Mub
31-32-33
34
35-36
37
38
Tightening torque for bolts
of shrink-disc (N.m)
12
30
30
59
100
Ø shrink-disc screws
M6
7xM8
10xM8 12xM10 10xM12
Do not tighten “cross-shaped” but “in one rotation”, starting at
the top right and following sketch bellow.
Tighteness of shrink disc screws to be controlled
periodically
Dismantling
1 -
Part-release the clamping screws evenly in stages in order
to avoid any tilting of the clamping flanges whilst taking great
care for safety reasons that the clamping screws are not
completely released from the thread bore as the pretensions in
the shrink-disc could cause the discs to jump apart.
2 -
Draw the shrink-disc off the hollow shaft, and if applicable,
clean oxidizing on shaft and hollow shaft bore.
2.1.2 - Shrink-disc exploded view, part list
4
302
204
16
Mub
3132 32 33
34
35
36
37
38
Rep Description
Qty Qty Qty Qty Qty Qty Qty Qty
16 Shrink-disc cover
1
1
1
1
1
1
1
1
204 Cover fixing screw
2
2
2
2
2
2
2
4
302 Shrink-disc
1
1
1
1
1
1
1
1
3 - MAINTENANCE
Control after commissioning (50 hours of operation).
Check tightening of fastening screws and belt tensioning if
applicable.
Preventive maintenance visit.
- Check regularly that the recommendations concerning mech-
anical and electrical installation are still complied with.
- Lubrication : refer to corresponding documents.
- If the gearbox is fitted with a breather plug, make sure that the
vent hole of the plug is not obstructed.
- Inspect the seals.
- Clean the ventilation louvres of the motor.
- Lubricate the bearings of the motors fitted with grease nipples.
- Control the air gap of brake motors.
4 - LUBRICATION
For operation in ambiant temperature between -10°C and
+40°C, Manubloc 3000 reducer is shipped, as standard, with
mineral Extreme Pressure oil: EP ISO VG 220.
For oil-lubricated gearboxes, check oil level and eventually
top up if necessary.
You must use an oil of the recommended type.
Polyglycol lubricants cannot be mixed with mineral or synthetic
lubricants of a different type.
Maintenance oil change.
- Mineral oil: drain every 5000 hours of operation.
- Synthetic oil PAO (polyalphaolefine): drain every 25000
hours of operation.
From -30°C to +60°C: synthetic oil PAO ISO VG 150.
From -30°C to -10°C: synthetic oil PAO ISO VG 32.
From -30°C to +60°C and for use in the food industry: synthetic
oil PAO
H1
ISO VG 150.
Grease nipple on AP, Mub34, Mub35
Replace the grease ISO VG 100, NLGI 2 after 12 000h
(25°C ; 1500 min
-1
)
Storage
period
< 1 year
AP can be commissioned
without regreasing
>1 and <2
years
Regrease before commissioning
2 to 5 years
Dismantle AP. Clean it. Replace
the grease completely
Oil capacities.
The oil capacities shown in table (see § 4) are approximative
values and should be used only as reference in determining
how much oil to provide. The proper oil levels can only be
determined by:
- Mub 31 to 35: plug:
filling the reducer to the level of the plug
.
- Mub 36 to 38: dipstick (J):
adjust oil level between the 2
marks (up/down)
Содержание Leroy-Somer 3234
Страница 2: ......
Страница 9: ...en MANUBLOC 3000 Installation guide Drive systems Reference 4031 en 2019 04 i...
Страница 15: ...de MANUBLOC 3000 Inbetriebnahme Antriebssysteme Referenz 4031 de 2019 04 i...
Страница 21: ...es MANUBLOC 3000 Instalaci n Sistemas de accionamiento Referencia 4031 es 2019 04 i...
Страница 27: ......