NC-AD300E Manual

- 44 -

After completion of editing, writing to ROM and RAM, can be effective immediately.

5.3.4 Subsriber line Number Configuration

Goes to “LinePart->SLC->Line Part”

“ExtCaller”is the caller number for call out, “IntCaller”is the caller number for call between

extensions. Click to change the numbers. After completion of editing, writing to ROM and RAM,

can be effective immediately.

5.3.5 User Password Configuration

When using the phone instructions and desktop assistants password authentication is required.

Click to Edit, the password must be four of the numbers.

After completion of editing, writing to ROM and RAM can be effective immediately.

5.3.6 Call permissions

This can lock the extensions with different level of call permissions such as long distance call,

internation call

The higher the value the greater the access, if the line use HighPriority big than the value of call

routing access to all call routing.Then the call for this line will have high access.

Содержание NC-AD300E

Страница 1: ...NC AD300E PbX User Manual...

Страница 2: ...ure that the information in this manual is accurate and adequate If you use this manual when you encounter any problems and have any good suggestions please contact us ShenZhen NiceUC communication Te...

Страница 3: ...4 1 Terminal connection 14 4 2 Command States 15 4 2 1 Boot states 15 4 2 2 Runing state 15 4 2 3 from the boot state to running state 15 4 3 Startup Parameters 15 4 3 1 Check boot parameters 15 4 3...

Страница 4: ...r line Number Configuration 44 5 3 5 User Password Configuration 44 5 3 6 Call permissions 44 5 3 7 Hot number 45 5 3 8 Call Forward Settings 45 5 3 9 Do Not Disturb Setting 45 5 3 10 Number Convert 4...

Страница 5: ...nd IP network Multi router inter office management Intelligent router distribute and telephone traffic sharing CDR output support TCP or UDP Grouping switching management have PBX function like Pre re...

Страница 6: ...escription Interface to the back of the device The The The The back back back back of of of of 300E 300E 300E 300E as as as as shown shown shown shown Power 220V AC PCM interface provide the correspon...

Страница 7: ...t ring inner tip RX TX Analog interface to connect telephone line totally eight interfaces from UC1 to UC8 with RJ45 connector the sequence as shown 2 2 2 interface UC8 UC7 Pin number 1 2 3 4 5 6 7 8...

Страница 8: ...easy to install in 19 inch cabinet Power Power Power Power eqipment eqipment eqipment eqipment Full Full Full Full load load load load power power power power 60W E1 2M E1 2M E1 2M E1 2M PCM PCM PCM P...

Страница 9: ...ower line 1 article console line 1 article ethernet line 1 article Crossover cable E1 T1 line 2 pair RJ45 2 BNC data CD 1 piece 3 1 2 tools Essential Screwdriver Crystal head pressure pliers Wire cutt...

Страница 10: ...k cable one is Crossover cable the other is straight through If device connect to computer please use Crossover cable If connect to HUB use Straight Through cable Network cable at both end of RJ45 lin...

Страница 11: ...transfer line BNC if the opposite end of the side is RJ45 You can DIY it according the fllowing diagram 3 1 4 Enviroment a Power Requirements Voltage should be constant the electric current should be...

Страница 12: ...affecting their life Temperature Humidity Transport and storage Long term work conditions Short term work conditions Long term work conditions Short term work conditions 20 60 0 40 5 45 5 85 5 90 Des...

Страница 13: ...ly to components 3 2 setup step At frist please install device and fixed and then connect the power cord turn the power switch observation equipment lights are normal To normal to connect serial cable...

Страница 14: ...configuration as shown Baud rate 115200 Data bits 8 Parity None Stop bits 1 Flow Control None Notes Computer usually have two serial ports COM1 and COM2 if it s out withUSB Serial port then may be CO...

Страница 15: ...s 4 2 2 Runing state After start up finished the Equipment will go to running state the prompt is In PC terminal you can view and modify the equipment operating parameters Running a large number of fu...

Страница 16: ...us row to make changes Enter Ctrl D exit change Directly press enter will move to the next one boot device at0 can not be changed processor number 0 can not be modified host name server can be freely...

Страница 17: ...onfig ip 192 168 16 100 ffff0000 the device IP address 192 168 16 100 the subnet mask for the hexadecimal form converted to decimal as 255 255 0 0 B ifconfig Use ifconfig command to query the device I...

Страница 18: ...sions 0 dropped lo unit number 0 Flags 0x8069 UP LOOPBACK MULTICAST ARP RUNNING Type SOFTWARE_LOOPBACK Internet address 127 0 0 1 Netmask 0xff000000 Subnetmask 0xff000000 Metric is 0 Maximum Transfer...

Страница 19: ...2 168 16 50 Enter gateway inet g 192 168 16 1 Enter user u pbxe Enter ftp password pw blank use rsh nice Enter flags f 0x20 Enter target name tn d Enter startup script s Enter other o Enter DeviceID 0...

Страница 20: ...imal as 255 255 0 0 ok means modification has been finished Note This method modify the IP to take effect immediately but don t save even after reboot take boot parameter Chapter 5 Software configurat...

Страница 21: ...bar will turn into gray such as At the same time the status bar will show Connect 5 1 2 Disconnect Click Button or in the Device menu select Disconnect If successful disconnect IP address bar will re...

Страница 22: ...vice parameters can be saved as a text file form The text file can be loaded into the device commonly used to restore the backup configuration Point Button or in the File menu select Import Note that...

Страница 23: ...tion of editing write to ROM and restart the device to take effect 5 2 2 Telnet service In the left side of configuration tool pleas click system parameters index and modify the parameters in the righ...

Страница 24: ...g the call signaling control 5 2 4 1 Clock Source E1 clock synchronization signal needs to be unity for working properly AD300E itself does not provide the clock source but it can get the clock from o...

Страница 25: ...ccess also known as Digital One DSS1 signaling the domestic usually 30 B channels plus one D channel 30B D approach B SS7 signaling SS7 signaling is a common international standard for common channel...

Страница 26: ...ck the ring back does not pass through the device will provide their own ring back tone rather than pass through the next level On the SS7 signaling parameters are as follows Link ID the Link ID in th...

Страница 27: ...n through E1 The default settings are usually able to successfully connect if client requests are special according to manually specify the DL value V5 2 signaling parameters are as follows CIC identi...

Страница 28: ...e of signaling SS7 you must first add the link parameter In Index area select SS7 signaling right click mouse button to add a new SS7 link in Parameter area This Can also be done in the Data menu sele...

Страница 29: ...XXX Backup link slot If use 2 SS7 link to back each other time slot for the back SS7 link load sharing Caller category caller attributes caller screening caller display called attributes specify the n...

Страница 30: ...ive L3 address is EFaddr types of PSTN signaling or control protocol message in the third layer of the address The aim is for the user port or public control functions provide a unique reference Goes...

Страница 31: ...conds the line will be in the status of hanging up pickup 50 ms means that after 50 ms that pick up the line status will be pick up Flash 70ms means if the hook up time is larger than 70ms and less th...

Страница 32: ...eans not detected FxsDialFirstKeyOver if user pick up phone but no dial up after this vlue then the line will be busy Set to 0 will always wait no busy FxsDialNextKeyOver if user pick up the phone and...

Страница 33: ...w Right click in the table pop up action menu can add and delete User Can also goes to Data menu operation Or use the toolbar Button operation Once added first select the Line Type then select line ra...

Страница 34: ...ch failed if this value not be set See figure above configuration for example in RuleID 0 when called number is 17909075526520000 then search process is as follows First check rules in grade 0 SID SID...

Страница 35: ...om the sequence small to large so when the small sequence failed route can goes to larger number sequence thus can back up for multi routes Action specify how to handle the call There are several opti...

Страница 36: ...ence in the group RoundInGroup each time when call in will select the timeslot one by one from beginning to the end SequenceInGroup always selct the timeslot from the beginning for each time call in o...

Страница 37: ...e a FXO line Second specifyLineRange as shown below Specify a range input the start number and end number of FXO lines third SpecifyLineGroups as shown below The designated group of FXO and the select...

Страница 38: ...ntents contents contents Example Example Example Example 1 Welcome Tips Welcome to XXX company 2 Operation Tips Please dial extension Number dial zero for help 3 Busy Tips user is busy now 4 No answer...

Страница 39: ...en the call will be terminated PromptVocIndex designate the welcome prompt tune main instruction tune and fail prompt tune voice index if you fill out 0 use the default voice Process using designates...

Страница 40: ...s as a logo Parameter It will be sent to the CTI program interface 3 SWitch 3 SWitch 3 SWitch 3 SWitch to to to to digital digital digital digital Trunk Trunk Trunk Trunk Transmitted Transmitted Trans...

Страница 41: ...n a call comes in extension FXS lines will be ringing according to the order line one by one To set up the lines in the queue group click description see below To set up a group please goes to SysPart...

Страница 42: ...uctions attached 5 8 Call Pick up Answer on behalf of the ringing extension by press defined function keys Usually set to 8 5 2 6 3 Groups Goes to SysPart Rule Router group you can set up groups for P...

Страница 43: ...below AD300E can specify three kinds of ringback tones Ext means the ringback tone when call from FXO Int means ringback tone between extensions Trans means ringback tone when answer foract After comp...

Страница 44: ...5 3 5 User Password Configuration When using the phone instructions and desktop assistants password authentication is required Click to Edit the password must be four of the numbers After completion o...

Страница 45: ...y transfer and non response transfer Call forwarding is an unconditional call forwarding any calls to this line will be automatically transferred to the call forwarding number BusyForwardNumber only w...

Страница 46: ...ROM and RAM can be effective immediately 5 3 11 login account setting Specify the telnet connection authentication account up to 10 accounts set up The index in the parameter area select login accoun...

Страница 47: ...vitural rules then it will After completion of editing write to ROM and RAM for effective Chapter 6 Calling detail records AD300E send out the CDR through net port For receiving CDR other software ne...

Страница 48: ...scription Description Description Description C Space space space left space left right r n String Example C 0 1 1 18 88889010 98888 5 Outbound lines and incoming line length is 4 the first one is lin...

Страница 49: ...in_channel out_channel The format of time year month day hour miniute second the year month day hour miniute second the year month day hour miniute second the year month day hour miniute second the fo...

Страница 50: ...load ok This is a DSP chip initialization information the format is dsp number function description loaded situation Number start from 0 Function including voice dtmf mfc metrec conference callerid an...

Страница 51: ...w basic basic basic basic information information information information ver ver ver ver Query the device software version devinfo devinfo devinfo devinfo Read device information pboot pboot pboot pb...

Страница 52: ...En logNetEn Enable the Ethernet port to send messages logNetDis logNetDis logNetDis logNetDis Close net mouth send a message logTerEn logTerEn logTerEn logTerEn Enable the serial port send a message l...

Страница 53: ...record 7 4 E1 monitor The small tools of NiceMonitor exe is to monitor the E1 status of AD300E Monitor use UDP network connections In the configuration tool interface the parameters of the index area...

Страница 54: ...NC AD300E Manual 54 After finished double click to open control device As shown...

Страница 55: ...The left boxes indicate the physical synchronization signal The right box indicate the HDLC link status Ss7Link Here is the status of signaling links on SS7 signaling Double click the sync box left y...

Страница 56: ...rt program Accessories Communication Hyper Terminal menu pop up New Connection wizard fill in names as HTCOM1 115200 then select one your favorite icon Click OK a dialog box appears as follows Select...

Страница 57: ...Restore Defaults change the bits per second to 115200 then click OK appears below thewindow This has been established you can save it to your desktop for easy use next time Click File Save As menu can...

Страница 58: ...ftware It is a small and easy to use FTP server program After the interface is running as follows Next create a new user Click Security menu select User right the following dialog box appears Click Ne...

Страница 59: ...box Check the appropriate option click OK Appendix 3 Recording tone and load to PBX You can use the recording software such as Windows system with a tape recorder to record tone Saved as a wav sound f...

Страница 60: ...Y to continue type N is cancel HOST server here to enter the FTP host IPIP address The default is server which is the IP address in startup parameters USER ad300e here to enter the FTP account name d...

Страница 61: ...ary Do not disturb off lock 11 0 Cancellation of the provisional don t disturb 12 1 Set do not disturb 12 0 Cancel do not disturb 13 SUB PHONE Unconditional call forwarding 13 0 Cancel unconditional c...

Страница 62: ...is cancel HOST server here to enter the FTP host IP address The default is server IP address in startup parameters USER ad300e here to enter the FTP account name The default is ad300e PASSWORD nice H...

Страница 63: ...ress complete no charge ADX Address complete coin box AFC Address complete charge subscriber free AFN Address complete no charge subscriber free AFX Address complete coin box subscriber free ADI Addre...

Страница 64: ...MPM Meter Pulse Message MUA Maintenance oriented group unblocking acknowledgement message NAM National area message NCB National call supervision message NNC National network congestion signal NSB Nat...

Отзывы: