NC-AD300E Manual
- 36 -
2) specify Line Range, as shown below:
Select PCM time slot from start to the end, note that for PCM0, the number of time slot is
from 0 to 31, for PCM1 is from 32 to 63, and so on.
3), specify the PCM group, as shown below:
In the PCM group you can select round in group or sequence in the group,
RoundInGroup, each time when call in will select the timeslot one by one from beginning to
the end.
SequenceInGroup, always selct the timeslot from the beginning for each time call in. only
busy to select the next one.
Members of group will be configured in the “Route->Group-> PCM”.
In the Attr column will configure the caller ID forward mode, bit-forward or one timeforward.
When using FXS to call out, you can specify the outbound Caller ID use"extension number" or "Direct
numbers."