NC-AD300E Manual
- 15 -
4.2 Command States
There are two status for device, after a normal boot into the running.if the startup was
interrupted, it will enter the Boot Status.
4.2.1 Boot states
When the device starts, if it has been connected to the terminal, you can see the start of the
initialization information.
When the
Press any key to stop auto-boot ...
are prompted to wait for a few seconds delay,
then press any key can stop the system start up and goes to boot state, and
"[Boot]:"
prompt will
be shown.
In boot state, the equipment is waiting for the basic parameter change such as network
parameters, boot methods.
4.2.2 Runing state
After start up finished the Equipment will go to running state, the prompt is
"->"
"In PC
terminal,you can view and modify the equipment operating parameters. Running a large number
of functions under the command will be described later.
Note that all commands are case-sensitive.
4.2.3 from the boot state to running state
In boot state, after the prompt of
"[Boot]:"
enter
"x",
the equipment will be loaded from the
Flash started into running state. If the FTP server has been configured, you can also type
"@",
the
equipment will be start to load the file from FTP server.
4.3 Startup Parameters
4.3.1 Check boot parameters
If in the boot state,
"[Boot]:"
enter
"p"
If in running state,
"->"
, enter" pboot "
boot parameter as follows:
boot device
:at
the system boot device name
unit number :0
Number of startup equipment unit