background image

14 – English

GB

CONNECTION CABLE FOR GEARMOTORS EQUIPPED WITH ELECTRONIC

LIMIT SWITCH - WITH SCREENING

Y

ellow/green

Blue

Black

Y

ellow/green

Black

Length L

Y

e

llow/green

Gr

een

W

hite

Pink

Br

o

w

n

Gr

een

Pink

W

hite

Y

ello

w

Y

ello

w

Gr

e

y

Or

ange

Gr

e

y

12 pole

9 pole

Содержание UST1K-1.1kW

Страница 1: ...ctions and information for installation and use The entire instruction manual is made up of instructions for using the motor and its control unit Automatic industrial door control unit UST1K 1 1kW UST...

Страница 2: ...LLATION 3 CONTROL AND CONNECTION ELEMENTS 4 MECHANICAL LIMIT SWITCH SETTING 7 DIGITAL LIMIT SWITCH SETTING 9 MOTOR CONNECTION CABLE 12 14 TERMINAL DIAGRAM 15 16 ELECTRONIC BOARDS OVERVIEW 17 18 TECHNI...

Страница 3: ...ture Description and use UST1K is a control unit for rolling shutters and sectional doors with three phase or single phase motors All the common safety elements can be connected With the application o...

Страница 4: ...ond to the direction of the arrown on the pressed button Now power up connect the EEC plug Limit switch setting g 3 The two OPENING and CLOSING limit switches must be connected like zero potential con...

Страница 5: ...button opening contact 4 Connection of the STOP OPEN IMPULSE and CLOSE control elements 3 5 7 4 6 8 STOP OPEN IMPULSE CLOSE X4 J15 J16 J17 J18 1 2 Triple button connection with 4 wire cable 3 5 7 4 6...

Страница 6: ...e with the programming y LED button faces the internal side of the housing It is necessary to set the speci c parameters on the K5 module if the OXI radio system is used For more details see the instr...

Страница 7: ...position Set the contact cam 3 E white so the limit switch is enabled 8white Additionallimitswitch2CLOSING 7green Additionallimitswitch2OPENING 6white Additionallimitswitch1CLOSING 5green Additionalli...

Страница 8: ...L 2 L 3 Motor UST1K 2 2kW board connection Capacitor UST1K connection X8 Capacitor yellow green blue brown blue brown blue brown black yellow yellow green blue brown blue brown blue brown black yellow...

Страница 9: ...t the door in the upper nal position by brie y pressing the UP button The control unit switches off in the nal position set with the EES limit switch If you want to move the upper nal position upwards...

Страница 10: ...2 X W 3 W 1 J 2 X Jumper 6 J 2 X 9 J 3 S 4 2 2 J 5 X 9 J 3 S 5 2 2 J 5 X 1 P 0 1 1 2 J 5 X J3 C 1 P 1 1 1 2 J 5 X J3 NC E 6 0 2 J 5 X B J2 E 7 0 2 J 5 X B J2 E 8 9 1 J 5 X J4 E 9 9 1 J 5 X J4 PE termi...

Страница 11: ...nary limit switch lower nal position Error 3 sensitive edge tripped for example In normal operating conditions the status of the door and or the number of the error present are shown on the display Op...

Страница 12: ...ED WITH ELECTRONIC LIMIT SWITCH WITH SCREENING Length L 4 pole Pink Green Brown White Yellow Grey 2 pole 3 pole Orange Violet Blue Yellow green Black 9 pole 12 pole Black 9 pole Blue 12 pole Yellow Gr...

Страница 13: ...TION CABLE FOR GEARMOTORS EQUIPPED WITH ELECTRONIC LIMIT SWITCH WITHOUT SCREENING Green Pink Brown White Yellow Grey 12 pole Green Pink White Orange Yellow Grey Yellow green Yellow green Length L Yell...

Страница 14: ...CABLE FOR GEARMOTORS EQUIPPED WITH ELECTRONIC LIMIT SWITCH WITH SCREENING Yellow green Blue Black Yellow green Black Length L Yellow green Green White Pink Brown Green Pink White Yellow Yellow Grey Or...

Страница 15: ...Thermal switch Preliminary limit switch CLOSED totally opened STOP 12V DC RS485 600mA T FUSIBLE BRAKE X9 X11 X3 1 9 8 7 2 3 4 5 6 X4 STOP CLOSE OPEN IMPULSE X5 24V DC X6 S 1 2 Lower sensitive edge LE...

Страница 16: ...ection Antenna screw terminal Coupling terminal of photoelectric barrier passage Plug connection for cover LED T2 setting button DIP switch Display Coupling terminal red traffic lights contacts with z...

Страница 17: ...CLOSING setting button Key switch connection Triple button connection Brake relay connection Antenna screw terminal Coupling terminal of photoelectric barrier passage Plug connection for assistance LE...

Страница 18: ...nection Antenna screw terminal Coupling terminal of photoelectric barrier passage Plug connection for cover LED T2 setting button DIP switch Display Coupling terminal red traffic lights contacts with...

Страница 19: ...TRANSPORT STORAGE DISPOSAL TECHNICAL ASSISTANCE SPARE PARTS ACCESSORIES We speci cally clarify that we neither carry out tests nor are we willing to approve any spare parts and or accessories not supp...

Страница 20: ...following harmonized standards EN 61000 6 2 2005 EN 61000 6 4 2007 The product also complies with the following directive in accordance with the requirements for quasi machines Directive 2006 42 EC OF...