background image

20 – English

GB

www.niceforyou.com

Nice SpA

Oderzo TV Italy
[email protected]

Our gearmotors and control units are

tested at TÜV-NORD

.

EC DECLARATION OF CONFORMITY

and declaration of incorporation of “quasi-machine”

Declaration in accordance with Directives: 2004/108/EC (EMC); 2006/42/EC (MD) annex II, part B

Note 

- The content of this declaration corresponds to the declaration at the last available version of the document fi led in the offi ces 

of Nice S.p.A. prior to the printing of this manual. This text has been adapted to meet editorial requirements. A copy of the original 
declaration may be requested from Nice S.p.a. (TV) I.

Declaration number:

441/UST1K

Rev.:

0

Language:

EN

Name of manufacturer:

NICE S.p.A.

Address: 

Via Pezza Alta N°13, 31046 Rustignè di Oderzo (TV) Italy

Person authorized
to provide technical
documentation:

Sig. Oscar Marchetto.

Product type:

Control unit for electromechanical gear-motors

Model / Type :

UST1K

Accessories:

Modules K3, K3A, K5, K7

The undersigned Luigi Paro, as Managing Director, hereby declares under his own responsibility that the product identifi ed above 
complies with the provisions of the following directives:

 

DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND COUNCIL of December 15 2004 concerning alignment 
of Member States’ legislation regarding electromagnetic compatibility and abrogating directive 89/336/EEC, according to the 
following harmonized standards:

EN 61000-6-2:2005, EN 61000-6-4:2007

The product also complies with the following directive in accordance with the requirements for “quasi-machines”:

 

Directive 2006/42/EC OF THE EUROPEAN PARLIAMENT AND COUNCIL of May 17 2006 regarding machines and amending 
directive 95/16/EC (consolidated text), according to the following harmonized standards:

 EN 13849-1:2008

I declare that the pertinent technical documentation has been prepared in accordance with Annex VII B to Directive 2006/42/

EC and that the following essential requirements have been met:

 1.1.1- 1.1.2- 1.1.3- 1.2.1-1.2.6- 1.5.1-1.5.2- 1.5.5- 1.5.6-

1.5.7- 1.5.8- 1.5.10- 1.5.11

The manufacturer agrees to send the national authorities pertinent information on the “quasi-machine” in response to a 

motivated request without affecting its intellectual property rights.

If the “quasi-machine” is operated in a European country with an offi cial language other than the language used in this 

declaration, the importer must associate a translation with this declaration.

The “quasi-machine” must not be operated until the fi nal machine in which it is to be incorporated is declared to conform to 

the provisions of Directive 2006/42/EC, if applicable to it.

The product also complies with the following standards:

EN 60335-1:2002 + A1:2004 + A11:2004 + A12:2006 + A2:2006 + A13:2008
EN 60335-2-103:2003

The parts of the product which are subject to the following standards comply with them:

EN 13241-1:2003, EN 12445:2002, EN 12453:2002, EN 12978:2003

Oderzo, November 4 2011

Ing. Luigi Paro

(Managing Director)

Содержание UST1K-1.1kW

Страница 1: ...ctions and information for installation and use The entire instruction manual is made up of instructions for using the motor and its control unit Automatic industrial door control unit UST1K 1 1kW UST...

Страница 2: ...LLATION 3 CONTROL AND CONNECTION ELEMENTS 4 MECHANICAL LIMIT SWITCH SETTING 7 DIGITAL LIMIT SWITCH SETTING 9 MOTOR CONNECTION CABLE 12 14 TERMINAL DIAGRAM 15 16 ELECTRONIC BOARDS OVERVIEW 17 18 TECHNI...

Страница 3: ...ture Description and use UST1K is a control unit for rolling shutters and sectional doors with three phase or single phase motors All the common safety elements can be connected With the application o...

Страница 4: ...ond to the direction of the arrown on the pressed button Now power up connect the EEC plug Limit switch setting g 3 The two OPENING and CLOSING limit switches must be connected like zero potential con...

Страница 5: ...button opening contact 4 Connection of the STOP OPEN IMPULSE and CLOSE control elements 3 5 7 4 6 8 STOP OPEN IMPULSE CLOSE X4 J15 J16 J17 J18 1 2 Triple button connection with 4 wire cable 3 5 7 4 6...

Страница 6: ...e with the programming y LED button faces the internal side of the housing It is necessary to set the speci c parameters on the K5 module if the OXI radio system is used For more details see the instr...

Страница 7: ...position Set the contact cam 3 E white so the limit switch is enabled 8white Additionallimitswitch2CLOSING 7green Additionallimitswitch2OPENING 6white Additionallimitswitch1CLOSING 5green Additionalli...

Страница 8: ...L 2 L 3 Motor UST1K 2 2kW board connection Capacitor UST1K connection X8 Capacitor yellow green blue brown blue brown blue brown black yellow yellow green blue brown blue brown blue brown black yellow...

Страница 9: ...t the door in the upper nal position by brie y pressing the UP button The control unit switches off in the nal position set with the EES limit switch If you want to move the upper nal position upwards...

Страница 10: ...2 X W 3 W 1 J 2 X Jumper 6 J 2 X 9 J 3 S 4 2 2 J 5 X 9 J 3 S 5 2 2 J 5 X 1 P 0 1 1 2 J 5 X J3 C 1 P 1 1 1 2 J 5 X J3 NC E 6 0 2 J 5 X B J2 E 7 0 2 J 5 X B J2 E 8 9 1 J 5 X J4 E 9 9 1 J 5 X J4 PE termi...

Страница 11: ...nary limit switch lower nal position Error 3 sensitive edge tripped for example In normal operating conditions the status of the door and or the number of the error present are shown on the display Op...

Страница 12: ...ED WITH ELECTRONIC LIMIT SWITCH WITH SCREENING Length L 4 pole Pink Green Brown White Yellow Grey 2 pole 3 pole Orange Violet Blue Yellow green Black 9 pole 12 pole Black 9 pole Blue 12 pole Yellow Gr...

Страница 13: ...TION CABLE FOR GEARMOTORS EQUIPPED WITH ELECTRONIC LIMIT SWITCH WITHOUT SCREENING Green Pink Brown White Yellow Grey 12 pole Green Pink White Orange Yellow Grey Yellow green Yellow green Length L Yell...

Страница 14: ...CABLE FOR GEARMOTORS EQUIPPED WITH ELECTRONIC LIMIT SWITCH WITH SCREENING Yellow green Blue Black Yellow green Black Length L Yellow green Green White Pink Brown Green Pink White Yellow Yellow Grey Or...

Страница 15: ...Thermal switch Preliminary limit switch CLOSED totally opened STOP 12V DC RS485 600mA T FUSIBLE BRAKE X9 X11 X3 1 9 8 7 2 3 4 5 6 X4 STOP CLOSE OPEN IMPULSE X5 24V DC X6 S 1 2 Lower sensitive edge LE...

Страница 16: ...ection Antenna screw terminal Coupling terminal of photoelectric barrier passage Plug connection for cover LED T2 setting button DIP switch Display Coupling terminal red traffic lights contacts with z...

Страница 17: ...CLOSING setting button Key switch connection Triple button connection Brake relay connection Antenna screw terminal Coupling terminal of photoelectric barrier passage Plug connection for assistance LE...

Страница 18: ...nection Antenna screw terminal Coupling terminal of photoelectric barrier passage Plug connection for cover LED T2 setting button DIP switch Display Coupling terminal red traffic lights contacts with...

Страница 19: ...TRANSPORT STORAGE DISPOSAL TECHNICAL ASSISTANCE SPARE PARTS ACCESSORIES We speci cally clarify that we neither carry out tests nor are we willing to approve any spare parts and or accessories not supp...

Страница 20: ...following harmonized standards EN 61000 6 2 2005 EN 61000 6 4 2007 The product also complies with the following directive in accordance with the requirements for quasi machines Directive 2006 42 EC OF...

Отзывы: