TITAN 912L Actuator
INSTALLATION REFERENCE MANUAL
10
|
www.hysecurity.com Nice/HySecurity, 6705 S 209th St, Ste 101, Kent, WA 98032 - TF: 800-321-9947 MX4685 Rev. A ©2019
1. Place gate in:
a) OPEN position for PULL-TO-OPEN configuration (IMAGE 4-1).
b) CLOSED position for PUSH-TO-OPEN configurations ( IMAGE 4-2).
2. With actuator arm fully retracted, rotate entire actuator on the pivot arm around until the gate
bracket attached to the actuator is positioned on a supporting structure of gate.
3. Mark position of gate bracket on gate or clamp into position.
4
POSITION GATE BRACKET ON GATE
GATE
OPEN
(PULL-TO-OPEN)
IMAGE 4-1:
PULL-TO-OPEN GATE BRACKET LOCATION
IMAGE 4-2:
PUSH-TO-OPEN GATE BRACKET LOCATION
ACTUATOR
PIVOT
ARM
GATE BRACKET LOCATION
ARMATURE
FULLY RETRACTED
GATE
CLOSED
(PUSH-TO-OPEN)
GATE BRACKET LOCATION
TRAFFIC DIRECTION
TRAFFIC DIRECTION
ARMATURE
FULLY RETRACTED
H I N G E
POST
WALL
H I N G E
POST
PIVOT ARM
ACTUATOR