Summary:

page

Instructions for automation installation and start-up

3

1

Working in safety

3

1.1 

Safety precautions and warnings

3

2

Product specifications

3

2.1

Product description, intended use and
technical data

3

3

Installation feasibility check

4

3.1

Check product components

4

3.2

Check suitability of environment

4

3.3

Check product application limits

4

4

Install the various components

4

4.1

Standard installation layout

4

4.2

Install the mechanical components

5

4.3

Laying electric cables

6

4.4

Manual lock and release procedure

6

5

Make electrical connections 

6

5.1

Connect all devices

6

5.2

Connect bluebus devices

8

5.2.1

Photocells

8

5.2.2

Photosensor FT210B

8

5.3

Connect devices to STOP input

8

5.4

Connect electrical power supply

9

6

Initial system start-up - checks

9

6.1

Operating test

9

7

Memorising devices and positions

9

7.1

Memorising devices

9

7.2

Memorising positions

10

8

Perform final testing of system

11

8.1

Final testing

11

8.2

Start-up

11

INTRODUCTION
This  manual  explains  how  to  install,  program  and  use  the
Soon  sectional  door  opening  automation.  The  various  sub-
jects are divided into three sections.

SECTION 1 is a step-by-step guide illustrating the phases re-
quired  for  physical  installation  of  the  product  and  operation
start-up.

SECTION  2  describes  how  to  personalise  operation  of  Soon,
by  the  programming  of  specific  functions  and  selection  of
special operations and settings.
There  is  also  a  section  on  maintenance  and  disposal  of  the
product.

The 

First

and 

Second Part

of the manual are aimed exclusively at

qualified Technical Personnel assigned to install the automation. None of
this information is relevant for the final user of the product.

!

9

Instructions for personalised automation
operation

12

9.1

Programming keys

12

10

Settings

12

10.1

Level 1 functions

12

10.2

Level 1 programming

13

10.3

Level 2 Functions (settable parameters )

13

10.4

Level 2 programming

14

11

Maintenance notification

14

11.1

Check of number of manoeuvres performed

15

11.2

Manoeuvre counter reset

15

12

Fault log list

15

13

Connecting other devices

15

14

Further details: special functions

16

14.1

“Always open” function

16

14.2

“Move anyway” function

16

15

Automation operation by means of transmitter
and “SM” radio receiver 

16

16

Automatic fault finding and diagnostics

16

17

What to do if… (Troubleshooting guide)

17

18

Disposal

17

Содержание Soon

Страница 1: ...ings for the fitter Istruzioni ed avvertenze per l installatore Instructions et recommandations pour l installateur Anweisungen und Hinweise f r den Installateur Instrucciones y advertencias para el i...

Страница 2: ...utomation The various sub jects are divided into three sections SECTION 1 is a step by step guide illustrating the phases re quired for physical installation of the product and operation start up SECT...

Страница 3: ...menta tion Before starting installation check whether other devices or mate rials are required to complete automation with Soon evaluating the specific application and associated risks for example co...

Страница 4: ...ell 3 Key operated selector switch 4 Post for photocell 5 Flashing light 6 Transmitter 7 Main edge Key to electric cables in Fig 3 A Electric power line B Flashing light with aerial C Photocells D Key...

Страница 5: ...1 Fig 4 a Insert the Soon outlet shaft in the sectional door drive shaft coupling them using the keys provided in the pack Perform this operation with the door CLOSED 2 Fig 4 b Secure the bracket to...

Страница 6: ...anual requires locking or release of the SOON mechanism Note The release or locking manoeuvres of the mechanism must be per formed exclusively with the gearmotor completely stationary The manual opera...

Страница 7: ...electric lock the FLASH output can be con nected to a 24V max 10W electric lock with latch versions with electromagnet only without electronic devices During the opening manoeuvre the electric lock is...

Страница 8: ...detec tors even not synchronised and enables the addition of other photo cells for example in the case of transit of heavy vehicles where a sec ond photocell is normally positioned at 1 m from the gr...

Страница 9: ...before proceeding Perform the following operations as specified and cross off the points as conformity of results is verified 6 Initial system start up checks 7 Memorising devices and positions 6 1 Op...

Страница 10: ...1 Led L2 remains lit Led L4 flashes Position RINT programming 7 If the intermediate slowdown position programming is not required press the key Set twice quickly to skip to the next programming led L4...

Страница 11: ...moving door are pro tected by means of impact force limitation measure the force as specified in the standard EN 12445 If speed and motor force controls are used as auxiliary functions with the syste...

Страница 12: ...the opening manoeuvre stops immediately after release of the photocells and automatic closure is activated with a pause of 5s The function Close After Photo is always disabled in manoeuvres interrupte...

Страница 13: ...e before automatic closure Applied only when auto matic closure function is enabled Sets the sequence of commands associated with the SS input or the 1st radio command Sets the motor speed during norm...

Страница 14: ...e not recommended to compensate for the fact that the leaf has anomalous points of friction excessive force may impair the safety system and damage the leaf If the Motor force control is used in suppo...

Страница 15: ...to L8 i e the input led associated with the parameter Fault log 4 Press and hold Set during steps 5 and 6 5 Wait approx 3s after which the leds corresponding to the manoeuvres subject to faults will...

Страница 16: ...erial terminal Fig 14 14 2 Move anyway function In the event that a safety device malfunctions or is out of service the gate may still be moved in hold to run mode For details refer to the paragraph C...

Страница 17: ...If no voltage is present this means that there is an electric overload on the output Check that there are no short circuits on the cable during the position memorisation phase led L1 or led L8 flashes...

Отзывы: