Pause Time

Funzione P.P.

Motor speed

FLASH
output.ì

Motor Force
on opening

Motor Force
on closing

L1
L2
L3
L4
L5
L6
L7
L8
L1
L2
L3
L4
L5
L6
L7
L8
L1
L2
L3
L4
L5
L6
L7
L8
L1
L2
L3
L4
L5
L6
L7
L8
L1
L2
L3
L4
L5
L6
L7
L8
L1
L2
L3
L4
L5
L6
L7
L8

10 seconds
20 seconds
40 seconds
60 seconds
80 seconds
120 seconds
160 seconds
200 seconds
Open - stop - close - stop
Open - stop - close- open 
Open - close - open - close
Apartment block
Apartment block 2 (more than 2” generates stop)
Step-step 2 (less than 2” generates partial open)
Hold-to-run
Opening in “semiautomatic”, closure in “hold-to-run””
Speed 1 (30% - slow)
Speed 2 (44%)
Speed 3 (58%)
Speed 4 (72%)
Speed 5 (86%)
Speed 6 (100% - fast)
Open V4, close V2
Open V6, close V4
Door Open Indicator
Active if door closed
Active if door open
Flashing light
Electric block
Electric lock
Suction cup
Maintenance indicator
Force 1 (low)
Force 2
Force 3
Force 4
Force 5
Force 6
Force 7
Force8 (high)
Force 1 (low)
Force 2
Force 3
Force 4
Force 5
Force 6
Force 7
Force8 (high)

10.3) Level 2 Functions (settable parameters)

Table 4: list of programmable functions: level 2

Input Led 

Parameter

Led (level)

Value

Description

Sets the pause time, i.e. the
time before automatic
closure. Applied only when
auto-matic closure function
is enabled

Sets the sequence of
commands associated with
the SS input or the 1st
radio command.

Sets the motor speed
during normal travel.

Selects the device
connected to the FLASH
output.

Sets the system for
controlling motor force, to
adapt it to the weight of the
door during the opening
manoeuvre.

Sets the system for
controlling motor force, to
adapt it to the weight of the
door during the closing
manoeuvre.

Note: “

“ represents factory settings

SEGUE

L1

L2

L3

L4

L5

L6

10.2) Level 1 programming

By default level 1 function are all set to OFF, but can be modified at any time as described below. Take care during modification procedures,
as there is a maximum time interval of 10 seconds between pressing one key and another; otherwise the system exits the procedure auto-
matically memorising the changes made up to that time.

Wait 10s to exit the programming mode automatically after the maximum time interval.

Note:

points 3 and 4 can be repeated during the same program-ming phase to set other functions to ON or OFF.

1.

Press and hold 

[Set] 

for approx. 3s 

2.

Release 

[Set]

when led L1 starts flashing.

3.

Press keys 

[

]

or 

[

]

to move the flashing led to the led associated with the function to be modified

4.

Press 

[Set]

to change the status of the function (short flash = OFF; long flash = ON) 

Содержание Soon

Страница 1: ...ings for the fitter Istruzioni ed avvertenze per l installatore Instructions et recommandations pour l installateur Anweisungen und Hinweise f r den Installateur Instrucciones y advertencias para el i...

Страница 2: ...utomation The various sub jects are divided into three sections SECTION 1 is a step by step guide illustrating the phases re quired for physical installation of the product and operation start up SECT...

Страница 3: ...menta tion Before starting installation check whether other devices or mate rials are required to complete automation with Soon evaluating the specific application and associated risks for example co...

Страница 4: ...ell 3 Key operated selector switch 4 Post for photocell 5 Flashing light 6 Transmitter 7 Main edge Key to electric cables in Fig 3 A Electric power line B Flashing light with aerial C Photocells D Key...

Страница 5: ...1 Fig 4 a Insert the Soon outlet shaft in the sectional door drive shaft coupling them using the keys provided in the pack Perform this operation with the door CLOSED 2 Fig 4 b Secure the bracket to...

Страница 6: ...anual requires locking or release of the SOON mechanism Note The release or locking manoeuvres of the mechanism must be per formed exclusively with the gearmotor completely stationary The manual opera...

Страница 7: ...electric lock the FLASH output can be con nected to a 24V max 10W electric lock with latch versions with electromagnet only without electronic devices During the opening manoeuvre the electric lock is...

Страница 8: ...detec tors even not synchronised and enables the addition of other photo cells for example in the case of transit of heavy vehicles where a sec ond photocell is normally positioned at 1 m from the gr...

Страница 9: ...before proceeding Perform the following operations as specified and cross off the points as conformity of results is verified 6 Initial system start up checks 7 Memorising devices and positions 6 1 Op...

Страница 10: ...1 Led L2 remains lit Led L4 flashes Position RINT programming 7 If the intermediate slowdown position programming is not required press the key Set twice quickly to skip to the next programming led L4...

Страница 11: ...moving door are pro tected by means of impact force limitation measure the force as specified in the standard EN 12445 If speed and motor force controls are used as auxiliary functions with the syste...

Страница 12: ...the opening manoeuvre stops immediately after release of the photocells and automatic closure is activated with a pause of 5s The function Close After Photo is always disabled in manoeuvres interrupte...

Страница 13: ...e before automatic closure Applied only when auto matic closure function is enabled Sets the sequence of commands associated with the SS input or the 1st radio command Sets the motor speed during norm...

Страница 14: ...e not recommended to compensate for the fact that the leaf has anomalous points of friction excessive force may impair the safety system and damage the leaf If the Motor force control is used in suppo...

Страница 15: ...to L8 i e the input led associated with the parameter Fault log 4 Press and hold Set during steps 5 and 6 5 Wait approx 3s after which the leds corresponding to the manoeuvres subject to faults will...

Страница 16: ...erial terminal Fig 14 14 2 Move anyway function In the event that a safety device malfunctions or is out of service the gate may still be moved in hold to run mode For details refer to the paragraph C...

Страница 17: ...If no voltage is present this means that there is an electric overload on the output Check that there are no short circuits on the cable during the position memorisation phase led L1 or led L8 flashes...

Отзывы: