EN
English –
15
TABLE 18 - FLASH Flashing light signalling
Fast flashing
Cause
ACTION
1 flash
1 second’s pause
1 flash
Bluebus error
At the starting of the manoeuvre, the devices connected to
BLUEBUS do not correspond to those recognized during the
recognition phase. One or more devices may be faulty; check
and, if necessary, replace them; in case of modifications repeat
the recognition process.
2 flashes
1 second pause
2 flashes
Triggering of a photocell
At the starting of the manoeuvre, one or more photocells do not
enable it; check to see if there are any obstacles. This is normal
when there is an obstacle impeding the movement.
3 flashes
1 second pause
3 flashes
Activation of the "motor force" limiting device
During the movement, the gate experienced excessive friction;
identify the cause.
6 flashes
1 second pause
6 flashes
The maximum manoeuvre limit/hour has been exceed
-
ed
Wait for a few minutes until the manoeuvre limiting device drops to
under the maximum limit.
7 flashes
1 second pause
7 flashes
There is an error in the internal electric circuits
Disconnect all the power circuits for a few seconds and then try to
give the command again. if the condition persists it means there is
a serious malfunction and the electronic board has to be replaced
8 flashes
1 second pause
8 flashes
A command that does not permit other commands
to be performed is already present.
Check the type of command that is always present; for example,
it could be a command from a timer on the “open” input.
4 flashes
1 second pause
4 flashes
Activation of the STOP input
At the start of or during the manoeuvre, the STOP input was acti
-
vated; identify the cause.
5 flashes
1 second pause
5 flashes
Error in the internal parameters of the electronic con-
trol unit
Wait at least 30 seconds, then try giving a command. if the con-
dition persists it means there is a malfunction and the electronic
board has to be replaced.
9 flashes
1 second pause
9 flashes
The automation mechanism has been stopped by a
“Stop automation mechanism” command
Release the automation mechanism by giving the “Release auto-
mation mechanism” command
TABLE 19 - Terminal LEDs on control unit
Bluebus LED
Cause
Solution
OFF
Malfunction
Check for presence of the power supply; check that the
fuses are not blown; in this case, identify the cause of
the fault and then replace with versions with the same
specifications.
ON
Serious malfunction
There is a serious malfunction; try switching off the
control unit for a few seconds; if the condition persists, it
means there is a malfunction and the circuit board has to
be replaced.
1 flash per second
All is OK
Normal control unit operation
2 fast flashes
There has been a change in the status of the inputs It is normal when there is a change to one of the inputs:
STOP, OPEN, triggering of photocells or the radio
transmitter is being used.
Series of flashes separated by a pause
Various
It is the same signal as for the flashing
of 1 sec-
ond
(see Table 20)
STOP LED
Cause
Solution
OFF
Triggering or STOP input
Check the devices connected to the STOP input
OFF
All is OK
STOP input is active
STEP-by-STEP LED
Cause
Solution
OFF
All is OK
STEP-by-STEP input is inactive
ON
Triggering of STEP-by-STEP input
Normal if the device connected to the S.S. input is active
OPEN LED
Cause
Solution
OFF
All is OK
OPEN input is inactive
ON
Triggering of OPEN input
Normal if the device connected to the OPEN input is
active
CLOSE LED
Cause
Solution
OFF
All is OK
CLOSE input is inactive
ON
Triggering of CLOSE input
Normal if the device connected to the CLOSE input is
active
10.4 - Signals on the control unit
The SLIGHT unit has a series of LEDs, each of which can give particular signals
both during regular operation and when there is a problem. Refer to table 19,
table 20 and the figure shown here.
Содержание SLH400
Страница 3: ...II 6 7 10 9 8 1 2 11 1 2 ...
Страница 5: ...IV 15 16 ...
Страница 7: ...VI 20 ...
Страница 8: ...VII 21 ...
Страница 28: ......
Страница 48: ......
Страница 68: ......
Страница 88: ......
Страница 108: ......
Страница 128: ......
Страница 148: ...IS0245A01MM_31 03 2015 www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com ...