TABELLA 17
-
Malfunctions archive
01.
Press and hold the “
Set
” key for about 3 seconds;
02.
Release the key when the “
L1
” LED starts flashing;
03.
Press key “
s
” or “
t
” to move the flashing LED onto L8, i.e. the “input LED” for the “malfunctions list” parameter;
04.
Press and hold the “
Set
” key; the “
Set
” key must be kept pressed during steps 5 and 6;
05.
Wait approx. 3s after which the leds corresponding to the manoeuvres subject to faults will light up. The L1 LED
indicates the result of the last manoeuvre and L8 indicates the result of the 8th manoeuvre. If the LED is on, this means
that a defect occurred during that manoeuvre; if the LED is off, this means that no defect occurred during that manoeuvre;
06.
Press keys “
s
” and “
t
” to select the required manoeuvre: the corresponding LED flashes the same number of times as
those made by the flashing light after a defect (see table 18);
07.
Release the “
Set
” key.
3 s
SET
SET
SET
SET
L1
or
and
3 s
L8
10.2 - Malfunctions archive
SLIGHT can display any faults that have occurred in the last 8 manoeuvres, for
example interruption of a manoeuvre due to activation of a photocell or sensi
-
tive edge. To check the list of faults, proceed as for Table 17:
10.3 - Flashing light signalling
During the manoeuvre the flashing light FLASH flashes once every second.
When something is wrong the flashes are more frequent; the light flashes twice
with a second’s pause between flashes.
WHAT TO DO IF…
(troubleshooting guide)
10
10.1 - Troubleshooting
Table 16 contains instructions to help you solve malfunctions or errors that may
occur during the installation stage or in case of failure.
TABLE 16 - Troubleshooting
Symptoms
Recommended check
The radio transmitter does not control the
gate and the LED on the transmitter does
not light up
Check to see if the transmitter batteries are exhausted, if necessary replace them
The radio transmitter does not control the
gate but the LED on the transmitter lights
up
Check to see if the transmitter has been memorised correctly in the radio receiver
No manoeuvre starts and the “BlueBUS”
LED does not flash
Check that SLIGHT is powered by a 230V mains supply.
Check to see if the fuses F1 and F2 are blown; if necessary, identify the reason for the failure and then
replace the fuses with others having the same current rating and characteristics.
No manoeuvre starts and the flashing light
is off
Make sure that the command is actually received. If the command reaches the STEP-BY-STEP input, the
corresponding “STEP-BY-STEP” LED must light up; if you are using the radio transmitter, the “BlueBus”
LED must make two quick flashes.
No manoeuvre starts and the flashing light
flashes a few times
Count the flashes and check the corresponding value in table 18
The manoeuvre starts but it is immediately
followed by a reverse run
The selected force could be too low for this type of gate. Check to see whether there are any obstacles;
if necessary increase the force
The manoeuvre is carried out but the flash
-
ing light does not work
Make sure that there is voltage on the flashing light’s FLASH terminal during the manoeuvre (being inter
-
mittent, the voltage value is not important: approximately 10-30Vdc); if there is voltage, the problem is
due to the lamp; in this case replace the lamp with one having the same characteristics; if there is no
voltage, there may have been an overload on the FLASH output. Check that the cable has not short-
circuited.
The manoeuvre is carried out but the Open
Gate Indicator does not work
Check the type of function programmed for the S.C.A. output (Table 7)
When the light should be on, check there is voltage on the S.C.A. terminal (approximately 24Vdc). If
there is voltage, then the problem will have been caused by the light, which will have to be replaced with
one with the same characteristics. If there is no voltage, there may have been an overload on the S.C.A.
output. Check that the cable has not short-circuited.
F1
F2
Содержание SLH400
Страница 3: ...II 6 7 10 9 8 1 2 11 1 2 ...
Страница 5: ...IV 15 16 ...
Страница 7: ...VI 20 ...
Страница 8: ...VII 21 ...
Страница 28: ......
Страница 48: ......
Страница 68: ......
Страница 88: ......
Страница 108: ......
Страница 128: ......
Страница 148: ...IS0245A01MM_31 03 2015 www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com ...