background image

Dichiarazione di conformità

Declaration of Conformity

Dichiarazione CE di conformità secondo Direttiva 98/37/CE, Allegato II, parte B (dichiarazione CE di conformità del fabbricante)

according to Directive 98/37/EC, Annexe II, part B (CE declaration of conformity by manufacturer)

Numero

208/ROAD200

Revisione

:

0

Number

Revision

Il sottoscritto Lauro Buoro in qualità di Amministratore Delegato, dichiara sotto la propria responsabilità che il prodotto

The undersigned Lauro Buoro, managing director, declares under his sole responsibility that the following product:  

Nome produttore:

NICE s.p.a.

Manufacturer’s name

Indirizzo

Via Pezza Alta 13, 31046 Z.I. Rustignè, Oderzo (TV) Italia 

Address

Tipo

Motoriduttore elettromeccanico “ROAD200” con centrale incorporata 

Type

“ROAD200” electromechanical gearmotor with incorporated control unit 

Modelli

ROAD200

Models

Accessori:

/

Accessories

Risulta conforme a quanto previsto dalle seguenti direttive comunitarie:

Satisfies the essential requirements of the following Directives

98/37/CE (ex 89/392/CEE) DIRETTIVA 98/37/CE DEL PARLAMENTO EUROPEO E DEL CONSIGLIO del 22 giugno 1998 con-
cernente il ravvicinamento delle legislazioni degli Stati membri relative alle macchine

DIRECTIVE 98/37/CE COUNCIL of June 22, 1998, for the harmonisation of the legislations of member States regarding machines 

Come previsto dalla direttiva 98/37/CE si avverte che non è consentita la messa in servizio del prodotto sopra indicato finché
la macchina, in cui il prodotto è incorporato, non sia stata identificata e dichiarata conforme alla direttiva 98/37/CE.

As specified in the directive 98/37/CEE use of the product specified above is not admitted until the machine on which it is mounted has been
identified and declared as conforming to the directive 98/37/CEE. 

Inoltre il prodotto risulta conforme a quanto previsto dalle seguenti direttive comunitarie, così come modificate dalla Direttiva
93/68/CEE del consiglio del 22 Luglio 1993:

Furthermore, the product complies with the specifications of the following EC directives, as amended by the directive 93/68/CEE of the Euro-
pean Council of 22 July 1993: 

73/23/CEE DIRETTIVA 73/23/CEE DEL CONSIGLIO del 19 febbraio 1973 concernente il riavvicinamento delle legislazioni degli
Stati membri relative al materiale elettrico destinato ad essere adoperato entro taluni limiti di tensione

73/23/ EEC DIRECTIVE 73/23/EEC OF THE COUNCIL of February 19, 1973 for the harmonisation of the legislations of member States
regarding electrical equipment designed to be used within certain voltage limits

89/336/CEE DIRETTIVA 89/336/CEE DEL CONSIGLIO del 3 maggio 1989, per il riavvicinamento delle legislazioni degli Stati
membri relative alla compatibilità elettromagnetica

89/336/ EEC DIRECTIVE 89/336/EEC OF THE COUNCIL of May 3, 1989, for the harmonisation of the legislations of member States regard-
ing electromagnetic compatibility

Inoltre risulta conforme ai requisiti essenziali richiesti dall’articolo 3 dalla seguente direttiva comunitaria, per l’uso al quale i
prodotti sono destinati:

Furthermore, the product complies with the essential requisites specified in article 3 of the following EC directive, for the use the products
have been manufactured for:

1999/5/CE; DIRETTIVA 1999/5/CE DEL PARLAMENTO EUROPEO E DEL CONSIGLIO del 9 marzo 1999 riguardante le
apparecchiature radio e le apparecchiature terminali di telecomunicazione e il reciproco riconoscimento della loro conformità

1995/5/CE; DIRECTIVE 1999/5/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of March 9, 1999 concerning radio equip-
ment and telecommunications terminal equipment and mutual recognition of their conformity.

Oderzo, 26 Ottobre 2004

Oderzo, 26 October 2004

Amministratore Delegato

Managing Director

Lauro Buoro

Содержание Road200

Страница 1: ...installatore Instructions et recommandations pour l installateur Anweisungen und Hinweise f r den Installateur Instrucciones y advertencias para el instalador Instrukcje i uwagi dla instalatora Aanwi...

Страница 2: ...ommissioning 11 5 1 Testing 11 5 2 Commissioning 12 6 Maintenance and Disposal 12 6 1 Maintenance 12 6 2 Disposal 12 7 Additional information 12 7 1 Programming buttons 12 7 2 Programming 13 7 2 1 Lev...

Страница 3: ...plicitly provided for in these instructions is not permitted Improper use may cause damage and personal injury Risk analysis must be carried out before starting installation to include the list of ess...

Страница 4: ...3 Photocells 4 Main movable edge 5 Open stop bracket 6 Rack 7 Secondary fixed edge optional 8 Flashing light with incorporated aerial 9 ROAD200 10 Closed stop bracket 11 Radio transmitter 3 9 2 3 List...

Страница 5: ...this could damage ROAD200 and cause malfunctions or dangerous situations If there is an access door in the leaf or within the range of the gate movement make sure that it does not obstruct normal trav...

Страница 6: ...art of the rack 10 Open and close the gate several times by hand and make sure that the rack is aligned with the pinion with a maximum tolerance of 5mm Moreover check that the play of 1 2mm has been r...

Страница 7: ...neath the hole the cables enter through Make a hole in the rubber membrane which is slightly smaller than the diameter of the cables which have been collected together and insert the membrane along th...

Страница 8: ...special procedures on the input For more useful information about STOP see also Paragraph 7 3 1 STOP Input 1 5 Photocell input for safety devices such as photocells Cut in during closure inverting the...

Страница 9: ...ly 1 Press the PP button to open the gate Check that gate open ing occurs regularly without any variations in speed The leaf must only slowdown and stop when it is between 50 and 30 cm from the openin...

Страница 10: ...mand T2 button Pedestrian gate command T3 button Open command T4 button Close command Table 5 Memorization Mode I T1 button Open command Automation A T2 button Close command Automation A T3 button Ped...

Страница 11: ...r to ensure the maximum safety levels Testing can also be adopted as a method of periodically checking that all the various devices in the system are functioning correctly Testing of the entire system...

Страница 12: ...n the corresponding maintenance schedule 1 ROAD200 requires scheduled maintenance work every 6 months or 10 000 manoeuvres max after previous maintenance 2 Disconnect the power supply and buffer batte...

Страница 13: ...e lapses the procedure will finish automatically and memorize the modifications made up to that stage 1 Press the button Set and hold it down approx 3 s 3s 2 Release the Set button when L1 LED starts...

Страница 14: ...te Points 3 to 7 can be repeated during the same programming phase in order to set other parameters Table 16 changing the adjustable parameters Example SET SET SET SET SET 7 2 5 Level one programming...

Страница 15: ...utoma tion system at any time In particular various devices types can be connected to STOP input as explained in paragraphs 7 3 1 STOP Input 7 3 1 STOP input STOP is the input that causes the immediat...

Страница 16: ...tructions if 2 pairs of photocells are used that could interfere with one another 7 4 1 Always open Function The Always open function is a control unit feature which enables the user to control an ope...

Страница 17: ...w for this type of door Check to see whether there are any obstacles if necessary increase the force 7 7 Diagnostics and signals A few devices issue special signals that allow you to recognize the ope...

Страница 18: ...ee Table 20 Off Activation of the STOP input Check the devices connected to the STOP input On Everything OK STOP Input active 27 L1 LED Description Function programming in progress If it flashes toget...

Страница 19: ...table for the automation of gates featuring leaves up to 5 m wide and weighing up to 200 kg as shown in Tables 1 and 2 Max absorbed power 150W 0 9A Insulation class 1 a safety grounding system is requ...

Страница 20: ...ery Absorption 25mA Battery life 1 year estimated on the basis of 20 commands day each lasting 1s at 20 C at low temperatures the efficiency of the batteries decreases Irradiated power 100 W Dimension...

Страница 21: ...and reliable activation However chil dren should not be allowed to play in the vicinity of automated systems to prevent any accidental acti vations keep all remote controls away from chil dren they ar...

Страница 22: ...must be repaired as soon as possible Replace the Remote Control Battery if your radio control after a period of time seems not to work as well or not to work at all it may simply be that the battery i...

Страница 23: ...ltre il prodotto risulta conforme a quanto previsto dalle seguenti direttive comunitarie cos come modificate dalla Direttiva 93 68 CEE del consiglio del 22 Luglio 1993 Furthermore the product complies...

Страница 24: ...e Sud Aubagne France Tel 33 0 4 42 62 42 52 Fax 33 0 4 42 62 42 50 infomarseille fr niceforyou com Nice Belgium Leuven Heverlee Tel 32 0 16 38 69 00 Fax 32 0 16 38 69 01 info be niceforyou com Nice Es...

Отзывы: