10 | EN
࿈
elero GmbH
The end positions for the blind are set directly on the
respective drive (not with elero 230 V assembly cable).
The drives draw their power exclusively from the battery
pack.
The 230 V power supply is used exclusively to charge
the battery pack.
The installation is carried out in the vicinity of the drive
in a double-height and double-depth installation box (not
included in the scope of delivery).
The blind is operated individually with an interlocked
push button or switch in a separate installation box or
in combination with the elero VarioTec-868 DC with a
separate elero radio transmitter.
It is also possible to connect a potential-free normally
closed or normally open contact to the central input, e.g.
via a smoke detector.
3.3 Delivery
condition
The battery pack is in power-saving mode with a low
charge and must
fi
rst be brought into an operational
state by charging it. The charging process can take up
to eight hours.
It is only fully ready for operation after it has been
charged for eight hours from the mains.
The end positions of the blind can be set only after the
ExitSafe system has been installed and the battery pack
has been fully charged on the drive itself.