DIP switch 4 ON & DIP switch 5 ON
Delayed maintained mode. If operated brie
fl
y, the drive is
activated only brie
fl
y. Only if it is operated for a longer period
does control of the drive remain active after the input signal
drops. This is helpful for adjusting venetian blind slats during
short operations.
5.6
Wire breakage recognition
This function is available only for the signal input
▲
. All
other inputs are designed for normally open contacts.
DIP switch 6 OFF
No wire breakage recognition. The command initiator at the
signal input
▲
is a normally open contact.
DIP switch 6 ON
Wire breakage recognition The command initiator at the input
Signal
▲
is a normally closed contact.
5.7
Shutdown and restart
Note the following points when switching o
ff
the power
supply over a longer period of time:
• If automatic retraction of the blind is activated, the
drive will be controlled automatically after some time
without the mains supply. To avoid this, disconnect the
battery pack.
• The battery pack will enter power saving mode after
several days without being recharged.
ExitSafe is not ready for operation in this state.
In order to be fully operational after the mains supply
has been switched on again, the battery pack must
fi
rst be charged for several hours.