18 | EN
࿈
elero GmbH
DIP
Function position
OFF
Function position ON
O
ff
| On
1
Individual control has
priority over master
control
Master control has priority over
individual control
2
A warning signal will
sound after two years
of operation or
500 charging cycles
of the battery pack.
No warning signal will sound
after two years of operation
or 500 charging cycles of the
battery pack.
3
The drive will not
be automatically
controlled UP at a
low battery pack
level.
The drive will be automatically
controlled UP at a low battery
pack level.
4
Push-button mode
Maintained mode
5
Maintained mode is
activated immediately
Maintained mode is activated
after a delay
6
Normally open
contact at the signal
input
▲
Normally closed contact at the
signal input
▲
(wire breakage
detection).
Table 4: Settings overview
4.6
Connection and installation
WARNING
Risk of injury, damage to the ExitSafe and
damage to the area surrounding the ExitSafe
due to improper electrical connections.