background image

5

Automatic gate openers are designed for 

vehicular traffic. They are powerful and can 

cause serious bodily injury or death. 

Accordingly, direct all pedestrian traffic 

to a separate walk-through gate.

 WARNING 

3 - SAFETY AND CAUTIONS 

2.2 - Gate latches 

In association with this gate controller and these operators, at no time should 

manual gate latches or locks be used. The forces applied to an operator 

could be in excess of those forces which are safe for bystanders. Should 

unnecessary forces be applied to a gate system which is in the locked 

position, the catastrophic failure of the gate or locking mechanism could 

result in substantial damage, extensive physical injury and or death. 

2.3 - Specific applications 

This gate operators are intended for those locations where vehicle traffic is 

intended to be controlled through the use of an entryway obstruction (gate). 

The gate system should be made of closed material types which prevent any 

body part from entering, becoming entangled or otherwise entering the gate 

in any manner. If the gate is not fully closed off from access, the opening or 

closing of the gate system may result in severe damage, injury or death. 

2.4 - Swing and slide gates 

Swing and slide gates are designed to move across an entry control point 

to prevent or allow controlled access by authorized persons or equipment. 

Swing or slide gate systems are not necessarily completely autonomous 

systems, and require regular maintenance and inspection on a periodic 

schedule. Although with certain safety devices in place the gate system could 

operate as a completely independent system free from human interaction for 

a defined period of time, human inspection and testing is required to ensure 

longevity and safe operation over long periods of time. 

2.5 - General requirements 

•  Safety and security are obviously a number one priority for both the 

manufacturer and the end user. As a result this manual has been written 

to make all persons fully aware of the responsibilities required to ensure 

constant safety, security and longevity are acquired throughout the life of 

the system. 

•  The manufacturer of this swing gate system has performed countless 

hours of testing, analysis and statistical control analysis to ensure that 

this operator performs its intended function for extended periods of time. 

The installer should ensure and verify that all required safety devices are 

installed correctly and in a manner consistent with the requirements of this 

manual. Additionally, all devices, security devices, safety devices, sensors 

and other affiliated attachments are installed in a robust manner that will 

prevent their accidental damage, removal or incidental tampering. 

•  A basic requirement for this system to operate correctly is that at any time 

a sensor is triggered, covered, disconnected or otherwise tampered with, 

that the entire system ceases to function. If any part of the gate safety 

system is removed or triggered, an immediate safety action by the gate 

operator is expected (retraction or stoppage). If the gate safety system is 

not functional, or fails to operate within these guidelines, the gate should 

be immediately removed from service until repairs can be made. 

•  Any gate system that is open or has slats, bars or other material which 

allows an individual to stick their hands, head, or feet through the material, 

must be converted or covered in such a manner so as to prevent such 

future actions. Application of materials, and how to modify the gate system 

is up to the end user or installer, however care should be taken to prevent 

such human interaction into the moving gate system. No entry into the 

gate is ever authorized and should be prevented by whatever measures are 

required for that specific installation. Care should always be used during 

installation! 

•  Loops and loop detectors, photo-cells or other equivalent devices must 

be installed with this gate operator to prevent the gate from closing on 

vehicular traffic 

•  The speed limit for vehicular traffic through the gate area is 5 MPH. Install 

speed bumps and signs to keep vehicular traffic from speeding through the 

gate area. Failure to adhere to posted speed limits can result in damage to 

the gate, gate operator, and to the vehicle. 

•  Be sure that all residents are familiar with the proper use of the gate and 

gate operator. Be sure that all residents are familiar with the possible 

hazards associated with the gate system. 

•  Be sure that all warning signs are permanently installed on both sides of 

the gate in an area where they are fully visible to traffic 

•  It is your responsibility to periodically check all reversing devices. If any of 

these devices are observed to function improperly, remove the operator 

from service immediately and contact your installing or servicing dealer. 

•  Follow the recommended maintenance schedule of one inspection per 

every 180 days of use. 

•  Do not allow children to play in the area of the operator or to play with any 

gate-operating device. 

•  Be sure that all activating devices are installed a minimum distance of 8 

feet away from the gate and gate operator, or in such a way that a person 

cannot touch the gate or gate operator while using the activating device. If 

activating devices are installed in violation of these restrictions, immediately 

remove the gate operator from service and contact your installing dealer. 

•  To remove the gate operator from service, operate the gate to the full 

open position, shut off power to the operator at the service panel, and 

disconnect batteries. 

IMPORTANT SAFETY INSTRUCTIONS 
WARNING - TO REDUCE THE RISK OF INJURY OR DEATH READ AND 

FOLLOW ALL INSTRUCTIONS. 

•  Never let children operate or play with gate controls. Keep the remote 

control away from children. 

•  Always keep people and objects away from gate. NO ONE SHOULD 

CROSS THE PATH OF THE MOVING GATE. 

•  Test the operator periodically. The gate MUST reverse on contact with a 

rigid object or stop or reverse when an object activates the non-contact 

sensors. After adjusting the force or the limit of travel, retest the gate 

operator. Failure to adjust and retest the gate operator properly can 

increase the risk of injury or death. 

•  Use the emergency release only when the gate is not moving. 

•  KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a 

qualified service person make repairs to gate hardware. 

•  The entrance is for vehicles only. Pedestrians must use separate entrance. 

•  SAVE THESE INSTRUCTIONS! 

3.1 - Properly installed safety devices 

Safety devices are used to sense, register and prevent damage to vehicular 

traffic which may block the path of the gate system. If properly installed and 

inspected for functionality within the prescribed maintenance procedures, the 

safety devices should prevent the gate system from inflicting harm or damage 

as a result of its opening and closing action.

3.2 - Safety signs, notices to personnel warning signs 

Safety devices must alert all who may enter the gate system area, as to 

the danger posed by moving equipment. Safety features must be installed 

and work correctly, such as the infrared beam. This safety device prevents 

serious injury or death as a result of the gate closing while an object or 

person blocks the gate operating pathway. An optional flashing lamp that 

is activated anytime the gate is moving should be added in addition to the 

aforementioned safety features. 

AUTOMATIC GATES ARE 

NOT FOR PEDESTRIANS!

Содержание H12-ETL-1K

Страница 1: ...Nice Apollo Swing Gate Opener Vehicular Swing Gate Operator Revision 1 0 0 0_2 2014 Model H12ETL 1K...

Страница 2: ......

Страница 3: ...ION 10 11 CONTROL BOX MOUNTING 11 12 MOTOR WIRING 11 13 LIMIT AND MOTOR CONNECTION TO THE BOARD 11 14 INCOMING POWER WIRING 12 15 LIMIT SWITCH ADJUSTMENT 13 16 REPLACE COVER 13 17 LEARNING MODE 14 18...

Страница 4: ...ction Dry contact inputs are provided for loop probe and photoelectric detectors as well as edge sensors guard station and fire department control of gate opening and closing Voltage outputs 12VDC and...

Страница 5: ...he moving gate system No entry into the gate is ever authorized and should be prevented by whatever measures are required for that specific installation Care should always be used during installation...

Страница 6: ...nal gate types 4 3 15 Any existing manual gate latches shall be removed or disabled when an automatic gate system is installed Use only mag locks controlled by the system 3 3 Gate system safety device...

Страница 7: ...nt any device that operates the gate opener where the user can reach around over or through the gate to operate the controls Controls should be mounted at minimum 8 feet away from any moving part of t...

Страница 8: ...IDENTIFICATION Accessory Output Connections Power Input Connections Motor Output Connections BlueBus Connection Master Slave Connection Accessory Input Connections Control Box 11111B Earth Ground H12...

Страница 9: ...size or hinge location Remove the cover from the motor assembly and store in a safe place with screws Remove motor assembly from the mounting bracket B A 17 3 4 B A inches 3 9 16 4 5 16 6 7 7 8 9 13 1...

Страница 10: ...ly Disengage the manual release as shown With the gate in the closed position push the arm towards the gate as shown Tack weld or C clamp the gate bracket in place Permanent welds or bolts should be c...

Страница 11: ...k green limit common yellow motor encoder signal blue common orange open limit switch white close limit switch 12 MOTOR WIRING Mount the control box within 4 feet of the motor assembly Do not mount th...

Страница 12: ...onnect wires to the battery terminal block The positive wire of the battery connects to the left terminal marked Note If the battery is connected backwards a red LED will illuminate below the terminal...

Страница 13: ...of the Control board hold the button down until the gate reaches the fully intended open position Adjust the Open Limit Switch until the GREEN light illuminates on the front of the control board The F...

Страница 14: ...irection MUST be set prior to learning the board 2 Press and hold the Open or Close button on the gate controller until the gate is 50 open 3 Press ENTER to allow the control board to scan for attache...

Страница 15: ...ars hard shutdown GUARD STATION Guard Station Open 34 Dry contact input for a guard station open switch Momentarily shorting the digital input to GND opens the gate to the full open position with the...

Страница 16: ...cting other assigned remote controls This procedure needs to be performed at the Nice Plug In Receiver with the affected Nice remote control 1 Press and hold the button on the side of the Nice receive...

Страница 17: ...d for the operator connection The wire table is based on stranded copper wire Wire run calculations are based on a 110 VAC power source with a 3 voltage drop on the power line plus an additional 10 re...

Страница 18: ...g edge of the closing gate The EXIT sensor input is provided to activate to open the gate or re open a closing gate upon sensing an exiting vehicle Figure FIRE DEPT INPUT 21 2 Magnetic lock connection...

Страница 19: ...ty equipment and connections Clean equipment and connections 22 6 Improper broken inadequately supported equipment wiring and conduit loose connections of terminals and loose ferrules 22 7 Poor mechan...

Страница 20: ...Photocells Figure LAYOUT FOR IN GROUND LOOPS Entrapment Protection Inputs Typical Installation Diagram Utilizing Photocells Figure LAYOUT FOR PHOTOCELLS Loop Safety Loop Safety Loop Shadow Loop Exit...

Страница 21: ...at the control panel before making any electric service power connection Be aware of all moving parts and avoid close proximity to any pinch points Know how to operate the manual release Adjust the un...

Страница 22: ...Stop gate movement Close the gate Figure GENERAL BOARD OVERVIEW THE PROGRAMMING BUTTONS INDICATED IN THE ABOVE REFERENCE SHOULD BE USED ONLY AFTER UNDERSTANDING THE MANUAL AND ITS RELATION TO THE PROG...

Страница 23: ...itivity of sudden impact force to the moving gate on a scale of 1 to 10 1 being most sensitive ESC Exit the FORCE menu 26 2 Speed Max Sets the limit of maximum allowed gate speed on a scale of 20 to 1...

Страница 24: ...dvance Settings The following settings are available for customizing the gate operator as required by the customer s installation requirements Set Language English Spanish French Set clock 12H 24H Set...

Страница 25: ...perator or system intended for use in a commercial location or building such as a multi family housing unit five or more single family units hotels garages retail store or other building servicing the...

Страница 26: ...Table 3 SYMPTOM S POSSIBLE SOLUTION Check that power to the circuit board is turned ON Check terminal block wiring for loose or broken wires If voltage measures OK check the terminal block Check the...

Страница 27: ...27 1 1 2 2 A A B B COMPANY NICE APOLLO NAME CONTROL BOX GENERAL OVERVIEW 18 22 18 18 8 32...

Страница 28: ...LE POLE 1115 1 4 SWITCH PUSH BUTTON CNTRL BOX 1119 1 5 1050 CIRCUIT BOARD 1050 1 6 1050 BOARD MOUNT KIT 10055090 1 7 NICE RECEIVER 318NPI 1 8 1 1 2 2 A A B B TITLE Company 2 6 8 3 7 4 5 1 Note Control...

Страница 29: ...the information from the dated proof of purchase receipt to confirm the warranty period or the technician will confirm your extended warranty period through your registration information on file The t...

Страница 30: ...30...

Страница 31: ...e and has tested the gate to make sure that the gate stops and reverses a short distance with minimal resistance applied Approximately 40 lbs on a swing gate at the end of the gate 8 The installer has...

Страница 32: ...Contact us Nice Group USA Inc 12625 Wetmore Road Suite 218 San Antonio TX 78247 Ph 1 210 545 2900 Fax 1 210 545 2915 www niceapollo com www facebook com NiceApollo...

Отзывы: