Start-up and inspection
START GUIDE
NOTE
There must be water in the climate system before
the switch is set to " ".
1.
Set switch (SF1) on VVM 310 to position "".
2. Follow the instructions in the display’s start guide. If the
start guide does not start when you start the VVM 310,
you can start it manually in menu 5.7.
TIP
See the section "Control – Introduction" for a more
detailed introduction to the installation’s control
system (operation, menus, etc.).
Commissioning
The first time the installation is started a start guide is star-
ted. The start guide instructions state what needs to carried
out at the first start together with a run through of the in-
stallation’s basic settings.
The start guide ensures that the start-up is carried out cor-
rectly and, for this reason, cannot be skipped.
During the start up guide the reversing valves and the shunt
valve are run backward and forwards to help vent VVM 310.
Caution
As long as the start guide is active, no function in
VVM 310 will start automatically.
The start guide will appear at each restart of
VVM 310, until it is deselected on the last page.
Operation in the start guide
language 4.6
If the start guide is left on this page it
closes automatically in
60 min
A.
Page
C.
Option / setting
B.
Name and menu number
A.
Page
Here you can see how far you have come in the start guide.
Scroll between the pages of the start guide as follows:
1.
Turn the control knob until one of the arrows in the top
left corner (at the page number) has been marked.
2. Press the OK button to skip between the pages in the
start guide.
B.
Name and menu number
Here, you can see which menu in the control system this
page of the start guide is based on. The digits in brackets
refer to the menu number in the control system.
If you want to read more about affected menus either con-
sult the help menu or read the user manual.
C.
Option / setting
Make settings for the system here.
NIBE VVM 310
Chapter 6 | Commissioning and adjusting
30