Further option information is available at
and in the
respective assembly instructions for the accessories used.
See page 57 for a list of the accessories that can be used
with VVM 310.
COMPATIBLE NIBE AIR/WATER HEAT PUMPS
Compatible NIBE air/water heat pump must be equipped
with a control board with a display with the minimum soft-
ware version indicated in the following list. The version of
the control board is displayed in the heat pump’s display (if
applicable) at start-up.
Software version
Product
118
F2020
55
F2025
55
F2026
all versions
F2030
all versions
F2040
all versions
F2120
all versions
S2125
all versions
NIBE SPLIT HBS 05:
AMS 10-6 + HBS 05-6
AMS 10-8 + HBS 05-12
AMS 10-12 + HBS 05-12
AMS 10-16 + HBS 05-16
all versions
NIBE SPLIT HBS 20:
AMS 20-6 + HBS 20-6
EXTRA HOT WATER HEATERS
Water heater with immersion heater
In a water heater with an immersion heater, the water is
initially heated by the heat pump. The immersion heater in
the water heater is used for keeping warm and when the
heat pump does not have sufficient power.
The water heater’s flow is connected after VVM 310.
EXTRA CLIMATE SYSTEM
In buildings with several climate systems that require differ-
ent supply temperatures, the accessory ECS 40/ECS 41 can
be connected.
A shunt valve then lowers the temperature to the underfloor
heating system, for example.
-EP21-RM1
-EP21-GP10
-EP21-BT2
-EP21-AA25
-EP21-BT3
-EP21-QN25
-EP21
CONNECTING HOT WATER CIRCULATION
A circulation pump can be controlled by VVM 310 to circulate
the hot water. The circulating water must have a temperat-
ure that prevents bacterial growth and scalding, and national
standards must be satisfied.
The HWC return is connected to a freestanding water heater.
The circulation pump is activated via AUX input in menu 5.4.
-QZ1-FQ3
-QZ1-GP11
-QZ1-RM1
-QZ1-RN1
-QZ1
NIBE VVM 310
Chapter 4 | Pipe connections