VENTILATOR SETUP

Download and install the software to setup the ventilator. 
Download link: 

http://www.nibe.se/dvc10 

Download the programme to control the ventilator and install it to your smart phone or tablet. 
Download link: 

https://play.google.com/store/apps/details?id=com.embarcadero.NIBE_DVC_10

https://itunes.apple.com/us/app/nibe-dvc-10/id1176860822?mt=8

Connection of the ventilator to PC:

 

Start the application NIBE DVC 10.exe at your PC. 

 

Take off the front part of the indoor unit for accessing the DIP switch and USB connector on the control board under the rubber cover. For details, please 
refer to Ventilator Setup).

 

Connect the ventilator and PC using a USB to mini USB cable.

 

Select the menu language prior to starting operation (3).

 

Select a required unit from the dropdown list 

Select device

 (1). When a ventilator is connected to a PC, the program automatically detects the connected 

ventilator and it is displayed in the dropdown list 

Select device

.

 

Select an operation mode for the ventilator in the network (2). Available parameters for the 

Master

 mode: 4-13. Available parameters for the Slave mode: 4-5.

1

2

Fan 

tab

4

7
6
9

10

11

3

5

8
12

13

14

Ventilator setup

Prior to starting setup of the unit open the tab 

Fan

•  Receive current parameters: 

reading the settings from the connected unit and saving the in the program. 

•  Restore default parameters:

 resetting the factory settings in the connected unit. 

•  Available OFF device (active by default):

 enabling/disabling of the unit turning off. The attempt to turn the unit off will turn it to low speed 

mode. To disable the function uncheck «Available OFF device». 

•  Direction:

 setting rotation direction of the fan in the 

Ventilation

 mode. This parameter sets the fan rotation direction in the 

Regeneration mode 

too.

IF SEVERAL VENTILATORS ARE INTEGRATED IN A COMMON NETWORK  

IT IS RECOMMENDED TO SET OPPOSITE ROTATION DIRECTION FOR EACH VENTILATION SET 

CONSISTING OF 2 UNITS TO AVOID EXCESSIVE OR NEGATIVE PRESSURE IN A PREMISE. 

•  Turn-off delay timer: 

setting reset time to a previous operation mode for the ventilator after activation of any connected sensors or the built-in 

humidity sensor. 

•  Night mode timer: 

setting reset time to the low speed mode after activation of the night mode, factory setting 8 hours. 

•  Party mode timer: 

setting changeover time for high-speed mode after activation of the Party mode, factory setting 4 hours. 

•  Humidity sensor: 

activation of the humidity sensor. When the indoor humidity exceeds the set point (12), the unit changes to the high speed. 

When the indoor humidity drops down below the set point, the turn-off timers starts countdown and then the unit changes to the previous speed. 

•  Relay sensor: 

activation of the external relay sensor (10). When the no-contact of the external relay sensor is closed, the unit changes to the high 

speed. When the no-contact is open the turn-off timers starts countdown and then the unit changes to the previous speed. 

•  0 - 10 V sensor: 

activation of the external analogue sensor 0-10 V. When a 0-10 V control signal value exceed the set point (13), the ventilator 

changes to the high speed. As the control signal value falls down below the set point, the turn-off timer starts its countdown and upon its elapsing 
the ventilator reverts to operation with the previous speed.

 

•  Apply: 

press the button (14) to apply the parameters in the selected tab.

Содержание DVC 10-50

Страница 1: ...USER S MANUAL Heat recovery single room reversible ventilator DVC 10 50 DVC 10 50L DVC 10 50W DVC 10 50WL...

Страница 2: ...eration NIBE DVC 10 hereinafter the unit as mentioned in the Safety Requirements and Manufacturer s Warranty sections as well as in warnings and information blocks CONTENTS SAFETY REQUIREMENTS Safety...

Страница 3: ...bstances in close proximity to the unit When the unit generates unusual sounds odour or emits smoke disconnect it from power supply and contact the Seller Do not open the unit during operation Do not...

Страница 4: ...nces toxic substances dust pathogenic germs THE UNIT MAY NOT BE OPERATED BY CHILDREN OR PERSONSWITH REDUCED PHYSICAL MENTAL OR SENSORY CAPACITIES OR LACKINGTHE APPROPRIATETRAINING THE UNIT MUST BE INS...

Страница 5: ...Transported air temperature C F from 30 22 to 50 122 Noise level 1 m dB A Sones 20 27 30 20 27 30 Noise level 3 m dB A Sones 11 18 21 11 18 21 Noise level attenuation dB A Sones 42 42 Heat recovery e...

Страница 6: ...rol board and basic controls on the side wall of the indoor unit Sound absorbing material Prevents ingress of outer noise into the room Outer ventilation hood Prevents ingress of water and foreign obj...

Страница 7: ...erator it heats and moisturizes the regenerator transferring up to 97 heat energy In 70 seconds as the ceramic regenerator gets warmed the unit is switched to the air supply mode Cycle II Fresh intake...

Страница 8: ...wedges 0 3 mm 0 1 8 Fill the gap between the air duct and the wall with mounting foam A Polystyrene wedge min 3 mm Install the air duct in the wall in such a way as shown on the left Install the air...

Страница 9: ...detach the front part of the indoor unit from its back part Prior to mounting the front panel make sure that the thermal actuator rod is in the lowest position and the light indicator is at least two...

Страница 10: ...e front part of the indoor unit 9 Roll the sound absorbing layer to match the air duct diameter with the protecting paper layer outside Do not remove the paper layer Insert the sound absorbing roll in...

Страница 11: ...the electric connections Connect the wires to the terminal block located on the control board in compliance with the wiring diagram and terminal designations EXTERNAL WIRING DIAGRAM DVC 10 50 L DVC 10...

Страница 12: ...aster Slave 1 Slave N VENTILATOR SETUP DVC 10 50 L DVC 10 50W L Open the rubber cover DIP switch under the cover 1 2 3 4 5 6 7 8 ON DIP 1 2 3 4 DIP switch and USB socket under the cover Prior to opera...

Страница 13: ...80 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 Turn off delay timer After activation of the humidity sensor or a connected external device the ventilator goes to the high speed After return of the humidity an...

Страница 14: ...The ventilator operates in the supply or extract mode with a set speed The fan rotation direction depends on DIP switch positioning setting extract mode by default DVC 10 50W L The ventilator operate...

Страница 15: ...DIP switch positioning extract mode by default Party mode the timer activates operation of the unit with the high speed for a set time period 4 hours by default The setting may be edited during setup...

Страница 16: ...o disable the function uncheck Available OFF device Direction setting rotation direction of the fan in the Ventilation mode This parameter sets the fan rotation direction in the Regeneration mode too...

Страница 17: ...50W L Emergency shutdown of all the ventilators happens if the fan shutdown lasts above 5 seconds In case of emergency shutdown of any ventilator in a network all the other ventilators also stop Alarm...

Страница 18: ...peed by default for 8 hours The timer setting is set during setup of the ventilator via a PC or the mobile application Party mode high speed timer activation by default for 4 hours The timer setting i...

Страница 19: ...the network The Slave unit responds to a signal from the Master unit only Any other signals from other controls are ignored In this mode the ventilators ignore any other signals from the sensors In c...

Страница 20: ...e Select a required device from the dropdown list 1 Select Master for required device mode 2 Select No Wi Fi router for the connection type 3 Open the tab Wi Fi 4 Select the type of security for the M...

Страница 21: ...ttings of the Master unit and set the unit up for operation according to the diagram No 1 CONFIGURING THE UNIT IN SLAVE MODE ACCORDING TO THE DIAGRAM NO 1 1 4 5 7 8 9 6 10 11 2 3 Start the software at...

Страница 22: ...aster unit 9 It must be consistent with the IP address of the router This parameter enables coordinated operation of the ventilator with a cloud server through internet Apply and save the selected par...

Страница 23: ...le manual assigning of the IP address for the Slave unit The assigned address must match the current network and be unique Detection of a free IP address is described below Apply and save the selected...

Страница 24: ...Enter the connection name 7 Press the button 9 to confirm 2 1 3 4 6 5 8 9 7 MASTER UNIT DEMO MODE This mode is for temporary use i e demonstration of the unit operation in a sales shop No connection t...

Страница 25: ...e mobile device Open the page of the home connection 1 2 in the program menu Select the required connection 3 Activate the control function through the could server 4 2 1 4 3 Note if this function is...

Страница 26: ...3 to enter the account 1 2 3 Adding new connection Press the button 1 to add the new connection at the page of connection through the cloud server Enter the connection name 2 Enter ID number of the M...

Страница 27: ...emains the same To open the air duct pull the front panel through the specially designed recessions The fan automatically starts operating according to the actual speed setting Air duct blocking Air d...

Страница 28: ...l If the thermal actuator rod is up please wait about 2 minutes until it goes down Attention Please make sure the thermal actuator rod is in lower position during re installation of the front panel 2...

Страница 29: ...ing is allowed The filter rated service life is 3 years Even regular technical maintenance may not completely prevent dirt accumulation on the regenerator and the fan Clean the regenerator regularly t...

Страница 30: ...ng or the outer ventilation hood Tighten the screws of the unit or the outer ventilation hood TROUBLESHOOTING STORAGE ANDTRANSPORTATION REGULATIONS Store the unit in the manufacturer s original packin...

Страница 31: ...d the brand name with the information stated on the unit packing and in the user s manual User s failure to ensure timely technical maintenance of the unit External damage to the unit casing excluding...

Страница 32: ...to certify acceptance of the complete unit delivery with the user s manual The warranty terms are acknowledged and accepted Customer s Signature Seller s Stamp Seller s Stamp Installation Company Stam...

Страница 33: ...www nibe com 33 NOTES...

Страница 34: ...www nibe com 34 DVC 10 50 W NOTES...

Страница 35: ...www nibe com 35 NOTES...

Страница 36: ...NIBE155EN 01...

Отзывы: