71
NIBE BA-SVM 10-200
Section 13 |
Technical data
Technical data
*If the length of the refrigerant pipes exceeds 15 m, extra refrigerant must be added in the amount of 0.06 kg/m.
Outdoor unit
Unit
AMS 10-6
AMS 10-8
AMS 10-12
Starting current
A
5
Compressor
-
Twin Rotary
Max. nominal fan performance
(heating)
m
3
/h
2 530
3 000
4 380
Fan power
W
50
86
Defrosting
-
Reverse cycle
Hot water tank drip tray
W
Integrated 110
Integrated 100
Integrated 120
High pressure critical value
MPa (bar)
4.15 (41.5)
Low pressure switch-off value (15 s)
MPa (bar)
0.079 MPa (0.79)
Height
mm
640
750
845
Width
mm
800
780 (+67 valve cover)
970
Depth
mm
290
640 (+110 base rail)
370 (+80 base rail)
Weight
kg
46
60
74
Colour (two layers of powder coating)
-
Dark grey
Refrigerant amount
kg
1.5
2.55
2.90
Max. length of refrigerant pipe one-way
m
30*
Refrigerant pipe dimensions
-
Gas pipe:
ext. diameter 12.7 (1/2”)
Liquid line:
ext. diameter 6.35 (1/4”)
Gas pipe: ext. diameter 15.88 (5/8”)
Liquid line: ext. diameter 9.53 (3/8”)
Optional pipe connections
-
Right-hand side
Bottom / right-hand side/ back
Part no.
-
064 205
064 033
064 110
Type of product
Unit
BA-SVM 10-200/6 E/EM/R
BA-SVM 10-200/12 E/EM/R
Height
mm
1590
Required ceiling height
mm
2100
Width
mm
600
Depth
mm
610
Weight
kg
161
(124 - ONLY BA-SVM 10-200/6 R)
165
(128 - ONLY BA-SVM 10-200/12 R)
Maximum operating pressure of central heating system.
bar
3
Maximum hot water pressure
bar
10
Hot water tank volume
l
180
Maximum operating temperature of central heating
°C
65
Maximum hot water temperature
°C
65
Low-energy circulation pump clim. sys.
-
Yes
Safety valve. climate system
-
Yes, in the safety assembly
Expansion vessel
l
10
Additional heat
kW
4.5 (230V) / 9 (400V)
Rated voltage
V
1x230 / 3x400
Hot water tank corrosion protection
-
titanium anode (E, E EM) / Stainless Steel (R)
Maximum hot water capacity in accordance with EN16147
-
230 litres. 40°C
Energy class (in accordance with ErP. at supply temp.
55°C) applies to package AMS 10-12 + BA-SVM 10-200/12
and AMS 10-6 + BA-SVM 10-200/6
-
A++
Efficiency class / Load profile (hot water)
-
A/XL
Содержание BA-SVM 10-200 Series