PROGRAM SETTINGS
Program setting of AXC 30 can be performed via the
start guide or directly in the menu system.
Start guide
The start guide appears at first start-up after the heat
pump installation, but can also be found in menu 5.7.
MENU SYSTEM
If you do not make all settings via the start guide or need
to change any of the settings, this can be done in the
menu system.
Menu 5.2.4 - accessories
Activating/deactivating of accessories.
Select: "shunt controlled add. heat".
Menu 5.3.2 - shunt controlled add. heat
Here you can perform the following settings:
• activation of the prioritised additional heat function.
• minimum operating time.
• minimum boiler temperature at which the shunt will
start to regulate.
• shunt amplification.
• shunt waiting time.
Menu 5.6 - forced control
Forced control of the various components in the heat
pump as well as in the various accessories that may be
connected.
EM1-AA5-K1: Activation of relay for extra heating.
EM1-AA5-K2: Signal (close) to mixing valve (QN11).
EM1-AA5-K3: Signal (open) to mixing valve (QN11).
EM1-AA5-K4: Activating the circulation pump (GP10).
Menu 4.1.8 - smart energy source™ (option)
The function prioritises how/to what extent each docked
energy source will be used. Here you can select
whether the system will use the energy source that is
cheapest at the time. You can also select whether the
system will use the energy source that is most carbon
neutral at the time. If you want to prioritise additional
heat, set the values to 0.
Caution
Also see the Installer Manual for the main
product.
AXC 30 F-series | GB
52
F
Содержание AXC 30
Страница 1: ...Installer manual Accessory card IHB 2113 3 231464 AXC 30 UN ...
Страница 2: ...S series S1255 4 S series F series 45 F series ...
Страница 12: ...ELECTRICAL CIRCUIT DIAGRAM WIRING DIAGRAM SHUNT CONTROL ELSCHEMA SHUNTSTYRD 051055 8 AXC 30 S series GB 12 S ...
Страница 53: ...ELECTRICAL CIRCUIT DIAGRAM WIRING DIAGRAM SHUNT CONTROL ELSCHEMA SHUNTSTYRD 051055 8 53 AXC 30 F series GB F ...