General
This accessory is used to enable connection and control
of the following accessory functions. One AXC 30 is
required for each function.
In the control module, there are connections to enable
the connection and control of one of the following ac-
cessory functions. One, or more, additional accessory
functions require one AXC 30 each.
• shunt-controlled additional heat
• step-controlled additional heat
• extra climate system
• hot water comfort
• active cooling (4-pipe system)
• pool heating
• connection of several heat pumps.
COMPATIBLE PRODUCTS
• SMO 40
CONTENTS
Cable ties
4 x
Heating pipe paste
2 x
Insulation tape
1 x
AXC module
1 x
Aluminium tape
2 x
Temperature sensor
2 x
COMPONENT LOCATION, AXC MODULE
(AA25)
AA5-X4
AA5-S2
AA5-X2
AA5
AA25-X1
AA5-X9
AA25-FC1
ELECTRICAL COMPONENTS
Accessory card
AA5
DIP switch
AA5-S2
Terminal block, inputs
AA5-X2
Terminal block, communication
AA5-X4
Terminal block, outputs
AA5-X9
AXC module
AA25
Miniature circuit-breaker
AA25-FC1
Terminal block, power supply
AA25-X1
Designations according to standard EN 81346-2.