Chapter 3
5B Series Modules
©
National Instruments Corporation
3-5
SC-2311 User Manual
5B47 Linearized Thermocouple Input Module with
Cold-Junction Compensation
The 5B47 linearized thermocouple input module is capable of accepting
input signals from J, K, T, E, R, S, and B type thermocouples. The 5B47
also uses cold-junction compensation circuitry, which is part of the
SC-2311 accessory, to compensate for the parasitic thermocouples formed
at the input screw terminals of the SC-2311. The 5B47 linearly scales the
thermocouples temperature into a 0–5 V signal that is routed form the
SC-2311 to the E Series DAQ device for measurement.
You can insert and use the 5B47 linearized thermocouple input modules in
any of the eight 5B channels inside the SC-2311.