Appendix B
5B Series Module Data Sheets
©
National Instruments Corporation
B-37
SC-2311 User Manual
Input Protection
Continuous
240 V rms, maximum
*
Transient
ANSI/IEEE C37.90.1-1989
*
Output Resistance
50
*
Voltage Output Protection
Continuous Short to Ground
*
Output Selection Time
6 µs @ C
load
= 0 to 2,000 pF
*
Output Enable Control
Max Logic "0"
+1 V
*
Min Logic "1"
+2.5 V
*
Max Logic "1"
+36 V
*
Input Current "0"
0.4 mA
*
Power Supply Voltage
+5 V ±5%
*
Power Supply Current
30 mA
*
Power Supply Sensitivity, RTI
±2 µV/Vs%
±0.4 mV/Vs%
Mechanical Dimensions
2.275" x 2.375" x 0.595"
(57.8 mm x 59.1 mm x 15.1 mm)
*
Environmental
Temperature Range
Rated Performance
-25˚C to +85˚C
*
Operating
-40˚C to +85˚C
*
Storage
-40˚C to +85˚C
*
Relative Humidity
0 to 93% @ +40˚C noncondensing
*
RFI Susceptibility
±0.5% Span error @ 400 MHz, 5
Watt, 3 ft
*
* Specifications same as model 5B40.
1
Vz is the nominal input voltage that results in a 0 V output.
2
Includes the combined effects of repeatability, hysteresis, and nonlinearity and assumes R
L
> 50 k
.
Loads heavier than 50 k
will degrade nonlinearity and gain temperature coefficient.
3
The output common must be kept within ±3 V of power common.
Specifications subject to change without notice.
Copyright 1995-2000
Analog Devices, Inc.
All rights reserved.