NHRC-10 User Guide
Page 30
Copyright
1999, 2000, 2001 NHRC LLC. All Rights Reserved.
3.8 *5: Program Autodial Slots
The NHRC-10 Repeater Controller supports 100 autodial slots and 10 emergency
autodial slots. Each slot can be programmed, cleared, or the controller can say the phone
number stored.
3.8.1 Program an emergency autodial number
To program or say the phone number in an emergency autodial slot, use the *50
command:
*50<n><number>
where:
<n>
is the emergency autodial slot number. Valid range is 0 to 9.
<number>
the phone number to program into that slot. 1-15 digits. Leave this
blank to inquire.
If a slot is successfully programmed, the controller will say “OK.”
If the number is left blank, then the controller will read back the autodial slot contents.
Example:
To program emergency autodial #3 to be 602-473-5111, send the following
command with the controller unlocked: "*5036024735111”. The controller will say
"OK" if the command is accepted.
To inquire what the number is in emergency autodial #3 is, send the following command
with the controller unlocked: "*503”. In the case of the example above, the controller
will say "six zero two four seven three five one one one."
3.8.2 Clear an emergency autodial number
To clear (delete) an emergency autodial, use the *51 command:
*51<n>
where:
<n>
is the emergency autodial slot number. Valid range is 0 to 9.
If a slot is successfully cleared, the controller will say “OK.”
Example:
To clear (erase) emergency autodial slot #2, send the following command
with the controller unlocked: "*512”. The controller will say "OK" if the command is
accepted.