NHRC-10 User Guide
Copyright
1999, 2000, 2001, NHRC LLC. All Rights Reserved.
Page 25
3.6.1 Program a timer
The NHRC-10 timers are programmed as follows:
*3<nn><time>
where:
<nn>
specifies the timer to set. Valid range is 00 to 12. Both digits must be
present. Consult the NHRC-10 Timers by Number Table for the timer
number.
<time>
is optional. If present, it is the value to program the timer to. The valid
range for <time> is 0 to 255. If time is omitted, the current timer value
will be announced.
After a valid set timer command is received, the controller will announce the timer value,
i.e., “Timer one is fifty.”
NHRC-10 Timers, by Number
Timer
No.
Description
Timer
Resolution
Timer
No.
Description
Timer
Resolution
00
Hang timer long
.1
07
Time-out timer long
1
01
Hang timer short
.1
08
Time-out timer short
1
02
ID timer
10
09
DTMF mute timer
.1
03
Patch timer
10
10
Fan timer
10
04
Autodial timer
10
11
Tail message counter
1
05
Emergency
autodial timer
10
12
Phone ring counter
1
06
DTMF access
timer
10
Examples:
To program the patch timer to 3 minutes (180 seconds), send the following command
with the controller unlocked: "*30318”. If the command is accepted, the controller will
respond "timer three is eighteen."
To find out what the fan timer is set to, send the following command with the controller
unlocked: "*310”. If the fan timer was set for 120 seconds, the controller will respond
with "timer ten is twelve."
To set the long hang timer for 20 seconds, send the following command with the
controller unlocked: "*300200”. If the command is accepted, the controller will respond
"timer zero is two hundred."