background image

 

SEA DATA 

English 

 

13 

3.3 Instrument 

backlight 

 

1.   Press and hold PAGE  

 
 

2.   Select backlight level with PLUS  

 
 

3.   Set the light level with SET 

 
 
 
 
 
 
 
 
 
 

4 Function 

overview 

The functions in the Sea Data instrument are divided into 2 pages: 
SPEED and DEPTH.  
The selected page is indicated by the LCD mark at top of the display. 
 
Each page has 2 types of functions that can be displayed together: 
 
1. Main-function, 

displayed at the top of the display in 30 mm high digits.  

2.  Sub-function, displayed at the bottom part of the display in 17 mm high digits. 
 
You can easily customise your favourite combination of functions, (See 9). 
 
The instrument can display metric and imperial units.  
For unit selection, (see 8). 
 
For function overview and transducers needed to display each function, see below. 
 

2 sec 

Содержание NX Sea Data

Страница 1: ...Instrument Installation and Operation Manual NX Sea Data English...

Страница 2: ...SEA DATA English 1...

Страница 3: ...English SEA DATA 2 Edition April 2007...

Страница 4: ...SHA 16 DEPTH ALARM DEA 16 ANCHOR ALARM 16 BOAT SPEED BSP unit 16 Barometric pressure unit hPA 16 6 1 1 TRUE WIND ANGLE TWA 16 6 1 2 APPARENT WIND ANGLE TWA 17 6 1 3 TRUE WIND SPEED TWS 17 6 1 4 APPARE...

Страница 5: ...Speed C19 Unit m s 22 8 1 11 Adjustment of Wind Angle C20 000 ADJ 22 8 1 12 Damping of Wind Readings C21 SEA LOW 22 8 1 13 Key beep setting C22 OFF KEY 22 9 Maintenance and fault finding 23 9 1 Mainte...

Страница 6: ...6 2 Plastic cable strap 6 1 Nexus Network cable 0 3 m 1 2 ft 7 5 Cable protectors 0 25 mm 0 1 inch 8 5 Cable protectors 0 75 mm 0 3 inch 8 Registering this product Once you have checked that you have...

Страница 7: ...English SEA DATA 6...

Страница 8: ...not cut the cables too short Allow extra cable length at the Server so it can be disconnected for inspection without having to disconnect all attached cables Do not place sealant behind the display Th...

Страница 9: ...from the back Note The two nuts must just be tighten by hand only Run the Nexus Network cable from the WSI box to the instrument If you want to cut the Nexus Network cable to length disconnect 4 pole...

Страница 10: ...onto the instrument pins Press the cable in to the cable leads Mount the connection back cover with the screw 2 1 1Installing instrument to the WSI box All NX2 instruments are connected directly to t...

Страница 11: ...English SEA DATA 10 2 1 2Installing instrument to the NX2 Server All NX2 instruments are connected directly to the Nexus Network They all use the same colour coded 4 pole jack plugs...

Страница 12: ...the time Always wait for the text Init OK to be displayed before you press SET on the next instrument The first unit ID number is 16 then 17 and so on in the order which you press SET The example sho...

Страница 13: ...alarms or reset the timer MINUS Move to the next sub function In edit mode Decreases the shown value PLUS Move to the previous sub function In edit mode Increase the shown value SET Set or edit alarm...

Страница 14: ...rk at top of the display Each page has 2 types of functions that can be displayed together 1 Main function displayed at the top of the display in 30 mm high digits 2 Sub function displayed at the bott...

Страница 15: ...AR TOTAL LOG LOG Distance from 0 to 19999 NM The total log can not be reset START TIMER STA Count down timer can be set between 59 and 1 minute To start the timer from minus 10 minutes 10 STA press SE...

Страница 16: ...reading can be set to show distance from the water surface or from the keel Unit in meters m feet FT or fathoms FA The text alternates between the selected unit and DPT BATTERY BAT The Battery voltage...

Страница 17: ...he pre set value ANCHOR ALARM Aaudible and visual alarm is activated if the actual depth becomes less or deeper than the pre set values Set shallow SHA alarm to actual depth minus 1 5 m 5 FT then set...

Страница 18: ...d value By this last press on SET you have turned on the selected alarm function which is indicated by the minute sign above the last depth digit in the sub function 6 3 Set and turn on anchor alarm A...

Страница 19: ...e turned off on To turn the alarm off on press CLEAR The minute sign disappears appears When a triggered alarm has been silenced it will only be triggered again if the selected depth value differs by...

Страница 20: ...to SPEED page Select DEPH page and find the sub function TWS Press PAGE and SET together All digits flash To move and copy to SPEED page press PAGE To lock the function press SET Each time the SPEED...

Страница 21: ...ct calibration value press MINUS PLUS and PAGE as required To lock the selected value press SET 8 1 Calibration of speed C10 8 1 1 Return C10 RET To return to normal mode press SET 8 1 2 Unit for Spee...

Страница 22: ...C15 00 0 ADJ Calibration of the depth transducer position This option is used to select whether the displayed water depth is measured from the water level or the keel To measure from the keel use the...

Страница 23: ...tion channel C20 to 356 Example 2 If the wind angle is 4 from port when you sail drive the boat straight into the wind Set the calibration channel C20 to 004 8 1 12 Damping of Wind Readings C21 SEA LO...

Страница 24: ...e check the following points and make a list of All connected instrument and trancducers including their software version numbers Server software version number Nexus Network data bus ID numbers for e...

Страница 25: ...o reading For more information see manual for WSI box or NX2 Server 9 2 3 Error messages The following error messages can appear on the display ERROR 2 Nexus Network is missing check colour coded conn...

Страница 26: ...ents are polarity protected Power consumption at 12V Sea Data instrument 0 08W with maximum lighting 0 8W Server 0 2W Temperature range Storage 30 to 80 C 22 to 176 F Operation 10 to 70 C 14 to 158 F...

Страница 27: ...English SEA DATA 26 11 Waranty...

Страница 28: ...SEA DATA English 27...

Страница 29: ...English SEA DATA 28...

Страница 30: ...SEA DATA English 29 22907 1 Edition 1 Copyright Nexus Marine AB Kuskv gen 4 191 62 Sollentuna Sweden Tel 46 0 8 506 939 00 Fax 46 0 8 506 939 01 www nexusmarine se...