English SEA
DATA
22
8.1.9
Unit for Air Pressure, C18 (Unit hPA)
Unit for air pressure. Hecto Pascal (hPa) or Inch HG (INH).
8.1.10
Unit for Wind Speed, C19 (Unit m/s)
Unit for wind speed. Metre/second (m/s), knots (KTS) or Beaufort
(BF).
8.1.11
Adjustment of Wind Angle, C20 (000° ADJ)
Mast top unit misalignment adjust value or the so called ”A-fault”,
makes it possible to choose any horizontal mounting angle.
Example 1:
If the wind angle is +4° (from Starboard) when you
sail/drive the boat straight into the wind. Set the calibration
channel C20 to 356°.
Example 2:
If the wind angle is -4° (from port) when you sail/drive
the boat straight into the wind. Set the calibration channel C20 to
004°.
8.1.12
Damping of Wind Readings, C21 (SEA LOW)
Damping of wind information. Controls the response time of wind
changes. To change damping, press
SET
. To select damping
level, press
PLUS
and select from: LOW) 1 sec, (MED) 5 sec and
(MAX) 22 sec. To store the selected value, press
SET
.
Factory value is (LOW), for use in calm sea. But if the sea is
rough, you may want to ”stabilise” the readout on the display, then
select MID or (MAX). Damping is set separately for each
instrument.
8.1.13
Key beep setting, C22 (OFF KEY)
(On) = Sound when push buttons are pressed. (OFF) = no sound.
Содержание NX Sea Data
Страница 1: ...Instrument Installation and Operation Manual NX Sea Data English...
Страница 2: ...SEA DATA English 1...
Страница 3: ...English SEA DATA 2 Edition April 2007...
Страница 7: ...English SEA DATA 6...
Страница 27: ...English SEA DATA 26 11 Waranty...
Страница 28: ...SEA DATA English 27...
Страница 29: ...English SEA DATA 28...