Chapter 7: System Activation

 

NextgenID Command Center Server and Client Software  

Activating the BioAxs 9750™ 

Once the installation of the access panel hardware and its supporting components has been 
completed, the next step in the implementation process is DCM and BioAxs Panel Activation. 
 
The BioAxs 9750™ Access Panel is always implemented in a one-to-one relationship with a Door 
Commander Module (DCM).  The details of the cabling between these two components are 
covered in previous chapters of this guide.   
 
To prepare the system for activation, complete the following steps: 
 
Power the access panel 506 Door Controller Board (DCB) with 24 Volt DC Power 
Power the USB Extender and DCM units with 110V AC Power 
Ensure that a network cable (Category 5 Ethernet) is connecting the DCM to a local area or 
private network that provides connectivity between the DCM and the Command Center server. 
DHCP Client – The default configuration of the DCM unit is to come online as a DHCP Client (i.e. 
on startup/boot up it will search the network for a DHCP Server to receive a valid TCP/IP 
Address).  If no such server exists, connectivity establishment between the DCM and the 
Command Center server will fail (in this case use fixed IP Address as explained in option ii.) 
Fixed IP Address – To use a fixed TCP/IP Address on the DCM, connect a keyboard, mouse and 
monitor to the system prior to booting up.  Modify the TCP/IP settings to use a fixed IP Address 
instead of acting as a DHCP client. 
 
For logging onto the DCM system use: 
Username:  

administrator

 

Password:  

nextgenid 

 
Ensure that all Windows Services required for the Command Center application are ‘started’.  
These required services are: 
DoorCommanderRestartService 
NGIDDoorCommander 
Message Queuing 
MSSQL Server 
 
Each of these services will be configured to start automatically by default when the DCM is 
installed and configured at the factory.  To confirm that each of the above services are ‘started’ 
log on to the DCM computer and use the ‘Services’ console in the Administrative Tools folder of 
the computer’s Control Panel. 
 
Once each of the above steps has been completed or confirmed, the DCM and Access Panel are 
ready to be activated by your Command Center system.  For specific instructions on performing 
this task, refer to the Administration section of the 

Command Center System Administration and 

User Guide

Содержание BioAxs 9750

Страница 1: ...P N NG DOC BA9750 IOM BioAxs 9750 Multi Modal Biometric Access Panel Fingerprint Recognition with PIN and Card Reader Installation Operations Manual Version 1 9...

Страница 2: ...BioAxs 9750 Installation Operations Manual Version 1 9 Copyright 2005 NextgenID Inc All Rights Reserved 2 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 3: ...nstitute of Technology in the United States and or other countries Fire Safety Notice Never connect BioAxs Access Control devices or locks to doors gates or barriers without first consulting the local...

Страница 4: ...1 9 Copyright 2005 NextgenID Inc All Rights Reserved 4 Contacts Mailing Address NextgenID Inc 10226 San Pedro Suite 100 San Antonio TX 78216 USA By Phone Phone 210 530 9991 Fax 210 530 9992 Email supp...

Страница 5: ...4 Customer Installer Supplied Hardware and Cabling 14 ESD Precautions 15 CHAPTER 2 UNPACKING 16 Unpacking the BioAxs 9750 Access Control System 16 Verify Shipping Contents 17 Optional Equipment and Ac...

Страница 6: ...NID COMMAND CENTER SERVER AND CLIENT SOFTWARE 38 ACTIVATING THE BIOAXS 9750 38 CHAPTER 8 USING THE PANEL 39 PRE REQUISITES FOR PANEL USE 39 Hardware Installation 39 Access Panel Activation 39 Member E...

Страница 7: ...BioAxs 9750 Installation Operations Manual Version 1 9 Copyright 2005 NextgenID Inc All Rights Reserved 7 NOTES 47...

Страница 8: ...rated to meet customer requirements Multi Modal Authentication Protocol The BioAxs 9750 provides multi modal authentication modes meaning the facilities access control administrator can adjust the acc...

Страница 9: ...Center allows for complex granting of access privileges Users can be granted access to a particular door during defined days and or hours User Groups can be created to assign the same door privileges...

Страница 10: ...g Yes Fingerprint Enrollments per User Up to 10 Templates recommended 2 per user Fingerprint FAR 0 001 Fingerprint Lookup Modes Verification Identification 1 N 1 1 1 Few Fingerprint FRR After Capture...

Страница 11: ...er Duress Notification via selectable biometric Per fingerprint enrollment Multi Centric User and Panel Management Department Segmental Management Yes Operating Temperature Range 0 C to 60 C Standard...

Страница 12: ...all In order to ensure the highest level of performance for facial recognition the BioAxs 9750 should be mounted such that the bottom of the access panel enclosure is at a height of 50 1 2 inches from...

Страница 13: ...resentative for availability Ethernet Connectivity LAN The BioAxs 9750 Door Commander Module DCM requires a network connection to the NextgenID Command Center server across a 10 100 Mb s Ethernet netw...

Страница 14: ...ice load Earth Ground In order to protect the BioAxs 9750 Access Panel device from electro static discharge ESD The access panel requires a home run connection to Earth Ground 1 2 Warning NextgenID ma...

Страница 15: ...closure and Door Controller Module wall mount brackets 1 See Chapter 3 Hardware Specifications for specific hardware specifications 2 See Chapter 4 Wiring Specifications for specific details on cablin...

Страница 16: ...he BioAxs 9750 Access Panel without the back box wear an ESD preventive strap and use an antistatic mat to avoid possible ESD damage Unpacking the BioAxs 9750 Access Control System To unpack the BioAx...

Страница 17: ...ASP License Key USB P N NG FM HASP USB o Door Commander Module Part number will vary depending on configuration o BioAxs 9750 Access Panel Part number will vary depending on configuration Note The Bio...

Страница 18: ...kup time it is recommended that you replace the DC power supply battery every two to four years Test regularly according to manufacturers instructions DCM Uninterruptible Power Supply UPS An uninterru...

Страница 19: ...rm Shunt Request To Exit Operating Temperatures BioAxs 9750 Access Panel 0 C to 40 C Door Commander Module 0 C to 50 C DCM Communications Extender 4 C to 40 C Operating Relative Humidity BioAxs 9750 A...

Страница 20: ...GND Blue White 6 RX Green 7 ISOLATED GND Brown White 8 ISOLATED GND Brown Distance guidelines apply to wired networks Type Maximum Distance Hub to Hub 100BaseTX 5 Meters 16 4 Feet Hub to Hub 10BaseT 1...

Страница 21: ...AWG solid foil braid shield PVC jacket Or Equivalent Note 1 RCA Video Connector End suitable for the chosen cable type is necessary for connection to the Composite Video Input of the Door Commander U...

Страница 22: ...stallation of a BioAxs 9750 Access Control System Note A detailed large scale connection and wiring diagram is available on request P N NG DOC BA9750 IWDIAG To obtain a copy of the detailed connection...

Страница 23: ...to control access to a facility In this case the BioAxs Access Control System typically handles the tasks of user Identification and access rights verification The existing access control system handl...

Страница 24: ...elaying communications between the BioAxs 9750 Access Panel and the DCM The Communications Extender plugs directly into an available USB port on the DCM The DCM and the DCM Communications Extender sho...

Страница 25: ...or Commander Module Rear Panel View Mount the DCM Communications Extender Unit Locate and mount the DCM Communications Extender near the DCM The distance from the Communications Extender to an availab...

Страница 26: ...supplying battery backup Attach the DCM Communications Extender AC Adapter to the Rear of the Extender Unit Plug the Adapter into a UPS outlet supplying battery backup Install the 24VDC Access Panel P...

Страница 27: ...re should measure 50 1 2 from the floor Using the enclosed 9750 series enclosure as a template mark the wall locations for the Access Panel enclosure anchor points and cabling exit hole The cable exit...

Страница 28: ...twork hardware and software security policies have been implemented DCM Communications Extender Using the supplied USB host cable connect the DCM Communications Extender figure 9 to the USB 1 connecti...

Страница 29: ...BioAxs 9750 Installation Operations Manual Version 1 9 Copyright 2005 NextgenID Inc All Rights Reserved 29 Figure 12 BioAxs 9750 Access Panel...

Страница 30: ...BioAxs 9750 Installation Operations Manual Version 1 9 Copyright 2005 NextgenID Inc All Rights Reserved 30 Figure 13 506X DCB Connection Overview...

Страница 31: ...BioAxs 9750 Installation Operations Manual Version 1 9 Copyright 2005 NextgenID Inc All Rights Reserved 31 Figure 14 505X DCB Connection Overview...

Страница 32: ...14 above For additional information contact a NextgenID Support Representative DCM Communications Extender J2 Connect the Shielded Cat5 DCM Communications Extender Cable to the RJ45 connector on the...

Страница 33: ...OPT1 The door latch mechanism Magnetic Lock Electric Door Strike connections are made on terminal J6 POW NC NO COM GND Door Latch J6 Door Latch Power Depending on the type and manufacturer of your do...

Страница 34: ...mode as follows Door Latch Mode Configuration Options OPT1 Jumper Settings Normally Closed NC Typical for Magnetic Lock Normally Open NC Typically for Door Strike Alarm Input Points Enclosure Tamper A...

Страница 35: ...the RX receive side of terminal J22 For 12V readers connect Ground and Power leads to terminal J1 Card Reader Output Wiegand Out Connect the external Wiegand out leads to the ONE ZERO terminals on th...

Страница 36: ...lead to the VID connector of terminal J10 Connect the Video Signal ground lead to the GND connector adjacent to the VID terminal 12V DC power is provided on connectors GND and POW Remote Camera Volta...

Страница 37: ...TailgatingIR array to the R connector in the TAILGATE section of terminal J6 The factory installed 505x interconnection cable is required on J9 Detailed information for installation of the NoTailgatin...

Страница 38: ...e network for a DHCP Server to receive a valid TCP IP Address If no such server exists connectivity establishment between the DCM and the Command Center server will fail in this case use fixed IP Addr...

Страница 39: ...s Panel detailed instructions may be found in the Administration section of the Command Center System Administration and User Guide Member Enrollment and Privilege Assignment Members have been enrolle...

Страница 40: ...quired to complete the user authentication process Depending on the options in your BioAxs Panel verification credentials include Biometrics PIN Proximity Card CAC Card etc User Interaction Complete A...

Страница 41: ...r verification will be successful following a positive facial recognition OR fingerprint verification whichever comes first Upon successful member identification the panel will actively begin the proc...

Страница 42: ...ticate the member The text display and speaker will read Access Denied in this event Step 4 Access Validation Upon successful member validation the panel will automatically begin the process of valida...

Страница 43: ...ioAxs 9750 it was preconfigured for one of the following behaviors Code Description HD Default Wiegand OR PIN OR Fingerprint AA Fingerprint Only AB Wiegand plus Fingerprint CB PIN plus Fingerprint or...

Страница 44: ...a piece of adhesive cellophane tape on the window and peel it away Under heavy usage the window coating on some sensors may turn cloudy from the salt in perspiration In this case gently wipe the wind...

Страница 45: ...on the sensor window will not cause problems A large amount of dust may make it more difficult for readings Applying the sticky side of a piece of adhesive cellophane tape on the window and peeling it...

Страница 46: ...r for the sensor to acquire a good image of your finger you must place the pad of your finger not the tip in the center of the oval window and apply gentle even pressure Do not roll your finger Pressi...

Страница 47: ...BioAxs 9750 Installation Operations Manual Version 1 9 Copyright 2005 NextgenID Inc All Rights Reserved 47 Notes...

Страница 48: ...BioAxs 9750 Installation Operations Manual Version 1 9 Copyright 2005 NextgenID Inc All Rights Reserved 48 Notes...

Отзывы: