Door Latch Ground
Attach the ground connection from your door latch mechanism to the
GND
terminal in the DOOR LATCH section of Terminal Block J6.
Door Latch Operation Mode (OPT1)
Your latch mechanism may operate in either NORMALLY OPEN
(NO) or
NORMALLY CLOSED
(
NC) mode. Attach the power lead from your door latch
mechanism to either the NO or NC terminal in the DOOR LATCH section of
Terminal Block J6.
Configure the 506x
OPT1 Jumper
to operate in either NO or NC mode as follows
Door Latch Mode Configuration Options (OPT1 Jumper Settings)
Normally Closed (NC) – Typical for Magnetic Lock
Normally Open (NC) – Typically for Door Strike
Alarm Input Points
Enclosure
Tamper
Alarm
(J5)
The access panel enclosure comes with a tamper switch and leads pre-installed
at the factory. Connect the tamper switch leads to the TAMPER section of
terminal
J5
at the SW and GND connection points (polarity neutral)
Enclosure Tamper Switch (J5)
Door
Sensor
Switch
(J6)
Connect the door sensor switch leads to the DOOR section of terminal
J6
at the
SW and GND connection points (polarity neutral)
Door Sensor Switch (J6)
Alarm
Shunt
(J6)
Connect the alarm override release leads to the ALRM section of terminal
J6
at
the SW and GND connection points (polarity neutral)