BioAxs 9750™ Installation & Operations Manual. Version 1.9
Copyright
2005 NextgenID, Inc. All Rights Reserved
37
NoTailgatingIR (J6)
Connect the Transmit (-) lead from the NoTailgatingIR array to the [T-] connector in the
TAILGATE section of terminal J6
Connect the Transmit (+) lead from the NoTailgatingIR array to the [T+] connector in the
TAILGATE section of terminal J6
Connect the Ground lead from the NoTailgatingIR array to the [GND] connector in the TAILGATE
section of terminal J6
Connect the Receive (-) lead from the NoTailgatingIR array to the [R-] connector in the
TAILGATE section of terminal J6
Connect the Receive (+) lead from the NoTailgatingIR array to the [R+] connector in the
TAILGATE section of terminal J6
The factory installed 505x interconnection cable is required on J9.
Detailed information for installation of the NoTailgatingIR can be found in the NoTailgatingIR
Installation Manual
NoTailgaitingIR (J6), 506x to 505x Tailgating Interconnect (J9)
Powering the System
When all DCB connections have been completed, power may be applied to the system.
1. Power on the UPS supplying power to the DCM and DCM Communications
Extender. The DCM indicates power on with a Green Led on the Front Panel. If the
DCM power indicator is not lit, press the power button to turn it on.
Power Indicator
LED (Green)
DCM Front Panel
2. Apply Power to the 506X DCB by activating the 24V Power Supply.
Verify your connections and secure the faceplate to the enclosure and lock.