BioAxs 9750™ Installation & Operations Manual. Version 1.9
Copyright
2005 NextgenID, Inc. All Rights Reserved
21
Maximum DCM Extender Cable Distance: 100M (328ft)
DCM Communications Extender Pin Assignments
PIN Wire
Color
1 Orange
/
White
2 Orange
3 Green
/
White
4 Blue
5 Blue
/
White
6 Green
7 Brown
/
White
8 Brown
Access Panel Video Cable
Suggested P/N:
•
RG-59U, 23 AWG, solid, braid shield, PVC jacket
•
RG-6U, 18 AWG, solid, foil/braid shield, PVC jacket
•
Or Equivalent
Note
1 RCA Video Connector End suitable for the chosen cable type is necessary for
connection to the Composite Video Input of the Door Commander Unit
24V Power Cable
•
14 AWG 2 Conductor Cable
Alarm Input points
•
18 – 22 AWG shielded twisted pair.
Relay outputs
•
18 – 22 AWG shielded twisted pair.
Wiegand Signaling
•
18 AWG 6-conductors shielded twisted pair.
Earth Ground
Access Panel Earth Ground Connection
•
14 AWG Solid - 10 AWG Stranded
Note
cabling requirements subject to change without notice. Always consult local building
codes and regulations