Power Requirements
The BioAxs 9750™ access panel operates at 24 VDC requiring approximately 0.33 – 2.0
1
amps.
Consideration should be given to common ground requirements when integrating the BioAxs
9750™ with existing access control systems. Select a secure location for mounting the power
supply and associated cabling. The Door Commander Module (DCM) and the DCM
Communications Extender units require 120 VAC.
The power supplies should be:
•
Isolated from other equipment
•
Regulated and filtered
•
Protected by means of emergency power and/or battery backup providing at least 2
hours emergency backup power
Never connect the power supply to any device or component that may put transients on
the power supply line or cause the power signal to fluctuate improperly.
See
Chapter 3: Hardware Specifications
for additional information
1. Amperage requirements may vary based on optional accessory and external device load.
Earth Ground
In order to protect the BioAxs 9750™ Access Panel device from electro-static discharge (ESD)
The access panel requires a home run connection to Earth Ground
1, 2
.
Warning:
NextgenID may consider your warranty void if there is an improper earth ground
connection to the BioAxs 9750™ Access Panel
1. See
Chapter 3: Hardware Specifications
for specific hardware specifications
2. See
Chapter 4: Wiring Specifications
for details on specific cabling types
Cabling Runs / Conduit Installation
Consult local building codes and regulations when making cabling runs. The installer should
make every effort to minimize the amount of exposed conduit.
Installation Tools Required
•
RJ45 Crimper
•
Wire Cutters / Strippers
•
Coax RCA Crimper
•
Mini Screw Driver Set
•
Drill and Drill Bits for mounting hardware and accessories to walls
•
Carpenters Level
•
Tape Measure
•
Fish Tape – Pull Wire
Customer / Installer Supplied Hardware and Cabling
Below is a typical list of additional items required to install your BioAxs 9750™ Access Control
System. Due to the variances in local building codes and regulations, these items are to be
supplied by the customer/ installer. Please refer to the appropriate chapters in this document for