BioAxs 9750™ Installation & Operations Manual. Version 1.9
Copyright
2005 NextgenID, Inc. All Rights Reserved
27
Secured Entry
6"
Access Panel
Enclosure
4'-
2
1/2"
Un-Secure side of door
Note: this
measurement is
critical to the
supported user
height ranges
Figure 11: BioAxs 9750™series Enclosure mounting height
Figure 11 above shows the proper mounting height for the BioAxs 9750 Access Panel Enclosure.
The bottom of the enclosure should measure 50-1/2” from the floor.
Using the enclosed
9750 series enclosure as a template
, mark the wall locations for the Access
Panel enclosure anchor points and cabling exit hole. The cable exit hole should be at least 1” in
diameter to accommodate standard wiring installations.
In a typical installation, the required cabling will run hidden through wall and enter into the Access
Panel Enclosure through the cable exit hole. If your requirements differ, please consult with a
NextgenID Installation Specialist.
Select wall anchors recommended for the type of wall material and security needs at the installation
site.