7. A UL listed or CSA approved conduit connector must be provided
at each end of the power supply cable (at the range hood and at
the junction box).
8. When making the electrical connection, cut a 3.2 cm (1-1/4 in.) hole
in the wall. A hole cut through wood must be sanded until smooth.
A hole through metal must have a grommet.
9. When cutting or drilling into the wall or ceiling, do not damage
electrical wiring and other hidden utilities.
10. Wire sizes must conform to the requirements of the National
Electrical Code ANSI/NFPA 70 - latest edition*, or CSA Standards
C22.1-94, Canadian Electrical Code Part 1 and C22.2 No. 0-M91 -
latest edition** and all local codes and ordinances.
White (N)
Black (L)
Yellow/Green
(G)
BLACK ( Live )
WHITE ( Neutral )
GREEN/YELLOW/GREEN ( Ground )
* National Fire Protection Association Batterymarch Park Quincy,
Massachusetts 02269
** CSA International, 178 Rexdale Boulevard, Toronto, Ontario,
CANADA, M9W 1R3
WARNING
ELECTRICAL SHOCK HAZARD
Do not perform service on an electrically
live system. Disconnect the main electrical
supply before servicing this device.
Touching electrical connectors or other
exposed electrical circuitry inside this range
hood when they are energized could result
in death, serious bodily injury, or property
damage.