2.1.4 Configuring PS15 for Passive or Active Mode
Remove the six TORX screws that hold the connector panel (figure next page);
Remove the connector panel so that filter WAGO connectors become accessible;
In Passive Mode, WAGO connector from filter should be inserted in
“Passive In”, and speakers
WAGO connectors should be inserted in connector
“Passive Out”.
In Active Mode, WAGO Connector from filter should be directly connected into to speakers via
speakers WAGO connectors (passive filter is then bypassed).
CONNECTOR PANEL
PASSIVE MODE
ACTIVE MODE
2.1.5 Cabling
NEXO recommends the exclusive use of multi-conductor cables to connect the system: the cable kit is
compatible with all the cabinets, and there is no possible confusion between LF, MF and HF sections.
Cable choice consists mainly of selecting cables of the correct sectional dimension (size) in relation to
the load resistance and the cable length. Too small a cable section will increase both its serial
resistance and its capacitance; this reduces the electrical power delivered to the loudspeaker and can
also induce response (damping factor) variations.
For a serial resistance less or equal to 4% of the load impedance (damping factor = 25), the maximum
cable length is given by:
L
max
= Z x S
S in mm
2
, Z in Ohm, L
max
in meters
The table below indicates these values, for 3 common sizes.
Load Impedance (
)
2
3
4
6
8
12
16
Cable section
Maximum Length (meters)
1,5 mm² (AWG #14)
3
4.5
6
9
12
18
24
2,5 mm² (AWG #12)
5
7.5
10
15
20
30
40
4 mm² (AWG #10)
8
12
16
24
32
48
64
IMPORTANT
Long speaker cables induce capacitive effects – up to hundreds of pF depending on the
quality of the cable - with a low-pass effect on high frequencies. If long speaker cables
must be used, ensure that they do not remain coiled while in use.
Содержание PS Series
Страница 17: ...CONNECTION DIAGRAMS Page 17 82 5 CONNECTION DIAGRAMS 5 1 PS8 LS400 with PS8 TDController ...
Страница 18: ...Page 18 82 CONNECTION DIAGRAMS 5 2 PS8 LS400 with NXAMP4x1 ...
Страница 19: ...CONNECTION DIAGRAMS Page 19 82 5 3 PS8 LS400 with NXAMP4x4 ...
Страница 20: ...Page 20 82 CONNECTION DIAGRAMS 5 4 PS10 LS600 with PS10 TDController ...
Страница 21: ...CONNECTION DIAGRAMS Page 21 82 5 5 PS10 LS600 with NXAMP4x1 ...
Страница 22: ...Page 22 82 CONNECTION DIAGRAMS 5 6 PS10 LS600 with NXAMP4x4 ...
Страница 23: ...CONNECTION DIAGRAMS Page 23 82 5 7 PS15 Passive RS15 Omni with PS15 TDController ...
Страница 24: ...Page 24 82 CONNECTION DIAGRAMS 5 8 PS15 Passive RS15 Omni with NXAMP4x1 ...
Страница 25: ...CONNECTION DIAGRAMS Page 25 82 5 9 PS15 Passive RS15 Omni with NXAMP4x4 ...
Страница 26: ...Page 26 82 CONNECTION DIAGRAMS 5 10 PS15 Active with NXAMP4x4 ...
Страница 56: ...Page 56 82 TECHNICAL SPECIFICATIONS 9 1 2 Dimensions ...
Страница 59: ...TECHNICAL SPECIFICATIONS Page 59 82 9 2 2 Dimensions ...
Страница 62: ...Page 62 82 TECHNICAL SPECIFICATIONS 9 3 2 Dimensions ...
Страница 66: ...Page 66 82 TECHNICAL SPECIFICATIONS 9 5 2 U Bracket for PS10R2 VNT SSBRK10 Parts Dimensions ...
Страница 67: ...TECHNICAL SPECIFICATIONS Page 67 82 9 5 3 U Bracket for PS15R2 VNT SSBRK15 Parts Dimensions ...
Страница 70: ...Page 70 82 TECHNICAL SPECIFICATIONS 9 5 6 Truss hook for U bracket or Flying Rail VNT TCBRK Parts Dimensions ...
Страница 73: ...TECHNICAL SPECIFICATIONS Page 73 82 9 6 2 PS10R2 U Bracket VNI UBRK10 Parts Dimensions ...
Страница 74: ...Page 74 82 TECHNICAL SPECIFICATIONS 9 6 3 PS15R2 U Bracket VNI UBRK12 Parts Dimensions ...
Страница 77: ...TECHNICAL SPECIFICATIONS Page 77 82 9 6 6 Wall suspension for PS8 PS10 VNI WS10 Parts Dimensions ...
Страница 78: ...Page 78 82 TECHNICAL SPECIFICATIONS 9 6 7 Wall suspension for PS15R2 VNI WS15 Parts Dimensions ...