15
NEVER CONNECT AN UNREGULATED GAS
SUPPLY LINE TO THE APPLIANCE. USE
THE REGULATOR/HOSE ASSEMBLY
SUPPLIED.
This is a liquid propane configured grill. Do not
attempt to use a natural gas supply unless the
grill has been reconfigured for natural gas use.
Total gas consumption (per hour) of this
stainless steel gas grill with all burners on
“
HI
”
:
Main burner 40,000 Btu/hr.
Rear burner 13,000 Btu/hr.
Side burner 12,000 Btu/hr.
Sear burner 18,000 Btu/hr.
oven 16,000 Btu/hr.
Total
99,000 Btu/hr.
L.P. TANK REQUIREMENT
A dented or rusty L.P. tank may be hazardous
and should be checked by your L.P. supplier.
Never use a cylinder with a damaged valve.
The L.P. gas cylinder must be constructed and
marked in accordance with the specifications
for L.P. gas cylinders of the U.S. Department
of Transportation (DOT) or the National
Standard of Canada, CAN/CSA-B339,
Cylinders, Spheres and Tubes for
Transportation of Dangerous Goods; and
Commission, as applicable. Overfilling
prevention device (OPD) shall be provided on
cylinder & QCCI connection on the cylinder
valve, ANSI/CGA-V-1. The cylinder supply
system must be arrange for vapor withdrawal.
The cylinder must include a collar to protect
the cylinder valve. The cylinder must be
provided with a shut off valve terminating in an
L.P. gas supply cylinder valve outlet specified,
as applicable, for connection type
QCC1 in the standard for compressed gas
cylinder valve outlet and inlet connection
ANSI/CGA-V-1.
Manifold pressure: 11
”
(27.94cm) water
column (W.C.).
L.P. GAS HOOK-UP
Ensure that the black plastic grommets on the
LP cylinder valve are in place and that the
hose does not come into contact with the
grease tray or the grill head.
CONNECTION
Your stainless steel grill is equipped with gas
supply orifices for use only with liquid
propane gas. It is also equipped with a high
capacity hose/regulator assembly for
connection to a standard 20lb. L.P. cylinder
(18-1/4
”
(46.35cm) high, 12-1/4
”
(31cm)
diameter). To connect the L.P. gas supply
cylinder, please follow the steps below:
1. Make sure tank valve is in its full off
position (turn clockwise to stop)
2. Check tank valve to assure it has proper
external male threads (type 1 connection
per ANSIZ21.81)
3. Make sure all burner valves are in their off
position.
4. Inspect valve connections, port, and
regulator assembly. Look for any damage
or debris. Remove any debris. Inspect
hose for damage. Never attempt to use
damaged or obstructed equipment. See
your local L.P. gas dealer for repair.
Gas Hook - Up
Содержание 720-0536
Страница 53: ...53...