GAS HOOK-UP
NEVER CONNECT AN UNREGULATED GAS
SUPPLY LINE TO THE APPLIANCE. USE THE
REGULATOR/HOSE ASSEMBLY SUPPLIED.
This is a liquid propane configured grill. Do not
attempt to use a natural gas supply unless the grill has
been reconfigured for natural gas use.
Total gas consumption (per hour) of this stainless
steel gas grill with all burners on “HI”:
Main burners
50,000 Btu/hr.
Side burner
12,000 Btu/hr.
Total
62,000 Btu/hr.
L.P. TANK REQUIREMENT
A dented or rusty L.P. tank may be hazardous and
should be checked by your L.P. supplier. Never use a
cylinder with a damaged valve. The L.P. gas cylinder
must be constructed and marked in accordance with
the specifications for L.P. gas cylinders of the U.S.
Department of Transportation (DOT) or the National
Standard of Canada, CAN/CSA-B339, Cylinders,
Spheres and Tubes for Transportation of Dangerous
Goods; and Commission, as applicable. Overfilling
prevention device (OPD) shall be provided on cylinder
& QCCI connection on the cylinder valve,
ANSI/CGA-V-1. The cylinder supply system must be
arrange for vapor withdrawal. The cylinder must
include a collar to protect the cylinder valve. The
cylinder must be provided with a shut off valve
terminating in an L.P. gas supply cylinder valve outlet
specified, as applicable, for connection type
QCC1 in the standard for compressed gas cylinder
valve outlet and inlet connection ANSI/CGA-V-1.
Manifold pressure: (operating): 10” water column
(W.C.), (non-operating): 11.2” water column (W.C.).
L.P. GAS HOOK-UP
Ensure that the black plastic grommets on the LP
cylinder valve are in place and that the hose does not
come into contact with the grease tray or the grill head.
CONNECTION
Your stainless steel grill is equipped with gas supply
orifices for use only with liquid propane gas. It is also
equipped with a high capacity hose/regulator assembly
for connection to a standard 20lb. L.P. cylinder (18-1/4”
high, 12-1/4” diameter).
To connect the L.P. gas supply cylinder, please follow
the steps below:
1. Make sure tank valve is in its full off position
(turn clockwise to stop)
2. Check tank valve to assure it has proper
external male threads (type 1 connection per
ANSIZ21.81)
3. Make sure all burner valves are in their off
position.
4. Inspect valve connections, port, and
regulator assembly. Look for any damage or
debris. Remove any debris. Inspect hose for
damage. Never attempt to use damaged or
obstructed equipment. See your local L.P.
gas dealer for repair.
5. When connecting regulator assembly to the
20