17
OFF
LO
I GNI TE / HI
Searing Side Burner
1. If you have already attempted to light the searing side burner with the igniter, allow 5 minutes for any
accumulated gas to dissipate.
2. Insert a match into the lighting rod (A) as shown in fig.16. Ignite the match and insert through the cooking
grids (B) to the burner.
3. Press the control knob and rotes to the “HI” setting continuing to press the knob until the burner ignites.
The burner should light immediately.
4. If the burner does not light within seconds turn the knob to the “OFF” position, wait 5 minutes and try again.
Rotisserie Burner
Note:
Remove the warming rack when using
a match to light the rotisserie burner.
1. If you have already attempted to light the
rear rotisserie burner with the igniter,
allow 5 minutes for any accumulated gas
to dissipate.
2. Insert a match into the lighting rod (A) as
shown in fig. 16. Ignite the match and
hold next to the burner (B).
3. Press the control knob and rotate to the
“HI” setting. Once the burner ignites,
continue to press the knob for 15 seconds.
4. If the burner does not light within seconds
turn the knob to the “OFF” position, wait 5
minutes and try again.
Gas Conversion From LP to NG
This grill is portable and configured for use with Liquid Propane (LP Gas), which is delivered to the grill from
removable tanks (LP tanks and their use are covered elsewhere in this manual). If a Natural Gas connection is
available, the user may wish to change the gas delivery system to the more permanent Natural Gas supply.
This grill is certified for use with either Liquid Propane (LP Gas) or Natural Gas and comes complete with the
necessary parts to convert the grill for use with Natural Gas hose and regulator sold separately. The Nexgrill
patented Conversion Valves allows the use of Natural Gas without replacing the burners or entire valve
system.
The process of converting is relatively simple and can be accomplished by any handy homeowner. Nexgrill
suggests, however, that a qualified gas technician do the conversion. Your warranty may be voided if the
conversion is improperly completed. Please retain the parts supplied with the grill and these instructions so
the technician can do the conversion.
Orifice Chart
The different burner valves in this grill have different BTU ratings. This means that the quantity of gas coming
from each orifice varies in order to create the BTU's. The holes in the are orifices themselves drilled to different
Fig. 16
WARNING
MAKE SURE ALL CONTROL KNOBS & CYLINDER VALVE ARE IN OFF POSITION BEFORE CONVERTING.
For Main burners
For Searing Side burner
/ Rear burner
Figure 325
CSA International
Project 2070363
18 of 31