Chapter 9. Cell Types
8001009 Cellometer® Auto T4 User Manual Rev C
42
6
Maximum
–
Indicates maximum cell diameter to be counted.
7
Roundness
–
Indicates minimum roundness factor to be counted.
8
Contrast Enhancement
–
Defines contrast enhancement for cells in relation to the background.
9
Default Dilution Factor
–
Indicates if a default dilution factor should be used and enables entry of
a specific value.
10
Test Viability Default
–
Option indicating whether Test Viability is to be used as a default.
11
Sensitivity
–
Sensitivity value for staining of cells to be included in count.
12
Uniformity
–
Uniformity value for staining of cells to be included in count.
13
Very Dim Dead Cells
–
Indicates whether to include cells that do not pick up the dye well.
14
Decluster Edge Factor
–
Decluster setting identifying how well cell edges are defined.
15
Decluster Th Factor
–
Decluster intensity setting to be used comparing cell signals to background.
16
Do Not Decluster Clumps
–
Indicates whether decluster enhancement settings are to be used.
17
Use Template for Printing
–
Indicates whether to use a print template.
18
Set Default
–
Allows users to select a default print template.
19
Browse
–
Allows users to browse for an existing print template.
20
Edit
–
Allows users to edit an existing print template.
21
New
–
Allows users to create a new print template.
22
Use Template for Data.txt
–
Indicates whether to set a data template.
23
Set Default
–
Allows users to select a default data template.
24
Browse
–
Allows users to browse for an existing data template.
25
Edit
–
Allows users to edit existing data template.
26
New
–
Allows users to create a new data template.
27
Save button
–
Saves changes to parameter settings.
28
Print button
–
Prints cell type parameters.
29
Cancel button
–
Closes window without saving changes to parameter settings.
Note:
Cell types imported from the Nexcelom Cell Library cannot be modified. However, Nexcelom cell types can
be saved as a new cell type (i.e., by selecting the
Save as a New Cell Type
check box), renamed and then modified
to meet your requirements.
Содержание Cellometer Auto T4
Страница 1: ......
Страница 6: ...Table of Contents 8001009 Cellometer Auto T4 User Manual Rev C vi ...
Страница 12: ...Chapter 1 Introduction 8001009 Cellometer Auto T4 User Manual Rev C 6 ...
Страница 16: ...Chapter 2 Equipment Safety 8001009 Cellometer Auto T4 User Manual Rev C 10 ...
Страница 26: ...Chapter 5 Operation 8001009 Cellometer Auto T4 User Manual Rev C 20 ...
Страница 36: ...Chapter 6 Software GUI Elements 8001009 Cellometer Auto T4 User Manual Rev C 30 ...
Страница 46: ...Chapter 8 Counting and Analysis Workflow 8001009 Cellometer Auto T4 User Manual Rev C 40 ...
Страница 56: ...Chapter 9 Cell Types 8001009 Cellometer Auto T4 User Manual Rev C 50 ...
Страница 66: ...Chapter 13 Nexcelom Support 8001009 Cellometer Auto T4 User Manual Rev C 60 ...
Страница 70: ...Appendix A Consumables 8001009 Cellometer Auto T4 User Manual Rev C 64 ...
Страница 72: ...Appendix B Declaration of Conformity 8001009 Cellometer Auto T4 User Manual Rev C 66 ...