![Newton Security T-DAR T1000 Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/newton-security/t-dar-t1000/t-dar-t1000_installation-and-operation-manual_1680906061.webp)
61
Door Control
The configurable options of the
Door Control
section allow for adapting T-DAR to
the existing peripherals to correctly trigger the unit. The logic state for these devices,
as used by the T-DAR, is selected by clicking the check box that reflects the
installation. For example, if the door contact passes continuity when the door is
closed the door contact is said to be
closed
when the door is closed. The same
logic is true for the
Access Contact
and the
Alarm Reset
. If there is some question
about the setting here, use the following steps to diagnose the issue:
Door Contact
•
On the monitor tab, observe the count for door opens (reset the counts on the
setup I/O page if necessary).
•
Open and hold the door.
•
If the door opens count increments by one, the switch is set correctly.
•
If the door open count does not increment, close the door.
•
If the door open count increments now, then the switch is set incorrectly.
o
If the count does not ever change, switch the display mode to Show /O
and observe the display of the I/O function on the screen. I/O
assignments can be seen in Figure XX, page XX.
o
If no changes are observed on the screen during testing, verify wiring
of device and controller.
•
Set the switch correctly and re-test.
Valid Access Contact
•
On the monitor tab, observe the count for Valid Access Contact (reset the
counts on the setup I/O page if necessary).
•
Open and hold the door.
•
If the Valid Access Contact count increments by one, the switch is set
correctly.
•
If the Valid Access Contact count does not increment, close the door.
•
If the Valid Access Contact count increments now, then the switch is set
incorrectly.
o
If the count does not ever change, switch the display mode to Show /O
and observe the display of the I/O function on the screen
o
If no changes are observed on the screen during testing, verify wiring
of device and controller.
•
Set the switch correctly and re-test.
Содержание T-DAR T1000
Страница 12: ...12 Figure 2 T DAR Control Unit CAD...
Страница 14: ...14 Figure 4 T DAR Annunciator CAD...
Страница 16: ...16 Figure 6 T DAR Stereo Tracking Head...
Страница 18: ...18 F igure 8 T DAR Door Encoder...
Страница 20: ...20 Figure 10 T DAR Event Camera...
Страница 22: ...22 Figure 12 T DAR Cable Extender Amplifier CAD...
Страница 37: ...37 Figure 16 Typical Dry Configuration...
Страница 89: ...89...