NewTeam 1500-XT Скачать руководство пользователя страница 14

Guarantee/Service Policy

13

NEWTEAM 1500-XT

Part No. 404-0126 Issue 02/03

Guarantee

Thank you for purchasing a NewTeam product, which has been designed, manufactured and 
tested, in the U.K., to the highest standards.

Guarantee.

2 Years, 1 Year - Parts and Labour  

Second Year- Parts Only

This is provided that:

1. The guarantee registration card is completed and returned within ten days complete with a copy
of proof of purchase.

2. The product is installed and operated in accordance with our instructions and has not been 
misused or damaged.

This in no way affects your statutory rights as a consumer. 

The information on the Guarantee card helps NewTeam to process any claims and contact you about
your product and its maintenance if required. The registration of your personal details is
purely for NewTeam use, and the other information helps us to make products for the future.

NewTeam Shower products are designed, manufactured and tested to the highest standards.

Should a complaint arise, products are guaranteed against faulty workmanship and materials for a
period of 12 months from the date of purchase, when in domestic use (second year guarantee is parts
only). For your guarantee to be valid, your shower pump must be installed by a competent 
person, in accordance with the instruction manual.

NewTeam will repair or replace (at our option), free of charge, any faulty components during the guar-
antee period, provided it has been maintained and operated in accordance with our
instructions, and has not been misused or damaged.

Modification or repair of this product by person(s) not authorised by NewTeam will invalidate this
guarantee.

This guarantee applies to products purchased within the United Kingdom or Republic of
Ireland, but does not apply to products used commercially.

This guarantee does not affect your statutory rights.

Service Policy 

-  Replacement Parts Policy

IMPORTANT: 

In the event of product or component malfunction, DO NOT tamper with or remove the product
from site. Telephone NewTeam Customer Service Department on 01536 264 012 and be 
prepared with the date of purchase, model number and a description of the complaint.

Our service staff are fully qualified to advise on correct installation procedures and will be able
to diagnose whether the fault will require a replacement part or a visit from a NewTeam
engineer.

If required, a service call will be booked, and either yourself or an appointed representative (who
should be a person of 18 years or over) must be present during the visit.

All site visits to product within the guarantee period will be carried out free of any parts or 
labour charges provided the conditions of the guarantee have been adhered to. 

(Second year

guarantee is parts only)

All site visits to product out of guarantee will be subject to charges for parts and labour which
is payable by you or your appointed representative at the time of the visit. Charges will also be
levied on cancelled appointments, unless advised to NewTeam at least 24 hours in advance of
the agreed date and time.

We reserve the right not to undertake work where payment cannot be made to our engineer at
the time of the visit.

NewTeam hold stocks of components for all their range of products and these will be
maintained for the duration of their life.

Should a product be discontinued, spare parts stocks will be maintained, but in the event of a
part becoming unavailable NewTeam reserve the right to supply a substitute of equal quality.

The following payment methods can be used to obtain spare parts: 

By post, pre-payment of proforma invoice by cheque or postal order. 

By telephone quoting credit card (Mastercard, Visa or Visa Delta) details.

REPLACEMENT PARTS:

Tel: 01536 409 222 • Fax: 01536 409 201 • E-Mail:[email protected]

CUSTOMER SERVICE HOTLINE:
Tel: 01536 264 012 • Fax: 01536 409 201 • E-Mail:[email protected]

Содержание 1500-XT

Страница 1: ...BOOKLET FOR FUTURE REFERENCE NEWTEAM 1500 XT THERMOSTATIC POWER SHOWER DEAR INSTALLER WHEN YOU HAVE READ THESE INSTRUCTIONS PLEASE ENSURE YOU LEAVE THEM WITH THE USER IN THE EVENT OF ANY QUERY PLEASE...

Страница 2: ...Product Features 1 NEWTEAM 1500 XT NewTeam 1500 XT Integral pump Push fit fittings 3 spray massage handset Thermostatic control BEAB approval of safety 255mm 240mm...

Страница 3: ...SSIONING Refer to back cover for Guarantee Customer Service and Replacement Parts Policy In the event of any query regarding installation please contact the NewTeam Customer Service Department Tel 015...

Страница 4: ...wer must comply with the current I E E Regulations which includes earth cross bonding to all metal pipework IMPORTANT All plumbing should be completed before final electrical connections are made The...

Страница 5: ...the pipework open the hot and cold water taps 3 Make your connection into the hot water supply pipe from the cylinder ensuring that it is the first draw off below the expansion pipe tee to minimise th...

Страница 6: ...for correct installation Fig 3 Fixing points 1500 XT Collet Fig 4 Push fit fittings Cold Hot Removal of Front Cover and Control Knobs Please note that this product comes packaged with the front cover...

Страница 7: ...nd insert the mains wiring through the aperture at the top of the base moulding Ensure that the supply pipes are fully inserted into the mixer valve push fit connections and fix the unit to the wall 8...

Страница 8: ...wall to indicate the upper fixing screw position Screw centres are 605 mm approx 23 inches apart Drill the wall at the marked fixing position using a 6 mm drill and loosely fix the rail end checking...

Страница 9: ...ting valves and the electricity isolating switch and place the open end of the shower hose in the shower tray or bath 3 Set the temperature control knob to cold fully clockwise and press the Stop Star...

Страница 10: ...Do not at anytime use bath cleaning liquids powders or specified scratch cleaners on any surface finishes In order to avoid surface wear or chemical attack on any of your shower fittings when cleaning...

Страница 11: ...ong Inlet Elbow x2 not shown 9 SP 087 0091 TPE Cover 10 SP 087 0154 Mixer Valve Complete 11 SP 087 0505 Temperature Control Knob 12 SP 087 0503 Start Stop Button 13 SP 087 0504 Shower Boost Button 14...

Страница 12: ...Installer Notes 11 NEWTEAM 1500 XT...

Страница 13: ...Installer Notes 12 NEWTEAM 1500 XT...

Страница 14: ...tory rights Service Policy Replacement Parts Policy IMPORTANT In the event of product or component malfunction DO NOT tamper with or remove the product from site Telephone NewTeam Customer Service Dep...

Страница 15: ..._ 3 If the product is a replacement shower please state the type and make of the shower it is replacing ____________________________________________________________________________ 4 What influenced y...

Страница 16: ...NewTeam Ltd Customer Service Dept Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW 1st Fold 2nd Fold 3rd Fold Please tape down Please tape down Affix Stamp...

Отзывы: