14
Too high
Correct height
Too low
Incorrect centering
Correct centering
Figure 11
— Floating Height Adjustment and centering
2.4
Installing tables with the Doubler Interface
The following instructions are applicable only to those tables equipped with
the Doubler Interface. Figure 12 shows a typical Doubler Interface System.
1.
Use the procedures in Section 2.1.2 and 2.3.1 to assemble the isolators
for both table sections.
2.
Carefully uncrate each table top, noting the correct orientation indicated
on the crates. Carefully check the doubler faces for any damage that
might prevent them from fitting tightly together.
Figure 12
— Typical Double Interface System
3.
Position the isolators for one table section as described in Section 2.1.2.
Install valves on the appropriate isolators as shown in Figure 8.
4.
Install the first table section on the isolators as described in
Section 2.1.3.
Notice
gap
No gap
Above alignment tabs
Even with alignment tabs
Below alignment tabs
Содержание IPV
Страница 2: ...ii...
Страница 22: ...16 Figure 13 Double Bolt Tightening Sequence...
Страница 32: ...INSTRUCTION MANUAL Vibration Control System...
Страница 39: ...viii...
Страница 63: ...24...
Страница 64: ...25...